Results of a Randomised Controlled Cross-Over Trial on the Effect of Continuous Subcutaneous Glucose Monitoring (CGMS) on Glycaemic Control in Children and Adolescents with Type 1 Diabetes
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To study the feasibility and the influence on glycaemic control of continuous glucose monitoring (CGMS) in young patients with type 1 diabetes. DESIGN AND METHODS: A double-blinded, cross-over study was performed in 30 children (median age 11.1 years [range: 2.3 - 16.3], diabetes duration 2.1 years [0.2 - 7.1]). Patients were randomised into an open (A) or blind study arm (B). Both groups performed standardised self-monitoring blood glucose (SMBG) and received CGMS at the beginning of the study, at 3 and 6 months, each. In the blinded arm, patients and investigator were concealed from CGMS data. After 3 months, open and blinded study arms crossed over. Average glucose values and area under the glucose curve (AUC) per 24 h, above 180 and below 60 mg/dl were calculated from CGMS. Haemoglobin A1c (HbA1c) was measured at each study point. RESULTS: Despite comparable clinical characteristics between the 15 patients of each arm, mean HbA1c was slightly lower in arm A than in B at baseline (7.8 +/- 1.2 % vs. 8.4 +/- 1.1 %, p = 0.148), at 3 months (7.8 +/- 1.1 % vs. 8.3 +/- 1.1 %, p = 0.233), and significantly lower at 6 months (7.6 +/- 1.1 % vs. 8.5 +/- 0.9 %, p = 0.026). However, no significant change of HbA1c occurred within each arm (A, p = 0.183 and B, p = 0.823), irrespectively whether CGMS data were blinded or not. Likewise, mean glucose and hyper- or hypoglycaemia values did not change significantly. CONCLUSIONS: In this setting, CGMS did not decisively influence glycaemic control of a total study cohort. More frequent use of CGMS at shorter intervals in single patients with hyper- or hypoglycaemic problems may be of greater value than SMBG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Practice Guidelines for Multiple Endocrine Neoplasia Type 1 (MEN1)
Thakker, R. V., Newey, P. J., Walls, G. V., Bilezikian, J., Dralle, H., Ebeling, P. R., Melmed, S., Sakurai, A., Tonelli, F., & Brandi, M. L. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1230 · Cited by 1,477
Cryer, P. E., Axelrod, L., Grossman, A. B., Heller, S. R., Montori, V. M., Seaquist, E. R., & Service, F. J. (2009) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-1410 · Cited by 1,277
Francis, G. L., Waguespack, S. G., Bauer, A. J., Angelos, P., Benvenga, S., Cerutti, J. M., Dinauer, C. A., Hamilton, J., Hay, I. D., Luster, M., et al. (2015) · Thyroid · doi:10.1089/thy.2014.0460 · Cited by 1,238
Cryer, P. E., Davis, S. N., & Shamoon, H. (2003) · Diabetes Care · doi:10.2337/diacare.26.6.1902 · Cited by 1,160
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Metadata
- Authors
- Deiss, D., Hartmann, R., Schmidt, J., & Kordonouri, O.
- Venue
- Experimental and Clinical Endocrinology & Diabetes
- Publisher
- Georg Thieme Verlag KG
- Published
- 2006-03-29
- Volume
- 114
- Issue
- 02
- Pages
- 63-67
- ISSN
- 0947-7349 (ISSN-L)
- 1439-3646
- OpenAlex
- W2094622125
- Cited by
- 62
- References
- 0
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Results of a Randomised Controlled Cross-Over Trial on the Effect of Continuous Subcutaneous Glucose Monitoring (CGMS) on Glycaemic Control in Children and Adolescents with Type 1 Diabetes. https://app.cochat.ai/papers/10.1055/s-2006-923887
- The paper
- Deiss, D., Hartmann, R., Schmidt, J., & Kordonouri, O. (2006). Results of a Randomised Controlled Cross-Over Trial on the Effect of Continuous Subcutaneous Glucose Monitoring (CGMS) on Glycaemic Control in Children and Adolescents with Type 1 Diabetes. Experimental and Clinical Endocrinology & Diabetes. https://doi.org/10.1055/s-2006-923887
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.