The DOI matches its Crossref record.
Endoscopic ultrasound-guided fine-needle aspiration biopsy for lymphadenopathy of unknown origin
Abstract
BACKGROUND AND STUDY AIMS: The diagnosis of mediastinal and intra-abdominal lymphadenopathy is sometimes difficult, especially in patients who have no other primary lesions. Lymphoma is one of the main causes of this condition. Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a safe and accurate diagnostic procedure for lesions surrounding the gastrointestinal tract. However, diagnosing lymphoma using the EUS-FNA technique remains a diagnostic challenge, due to limitations in the amount of material sampled. The aim of the present study was to evaluate the yield of EUS-FNA biopsy (EUS-FNAB) using a large-gauge needle in patients with mediastinal and intra-abdominal lymphadenopathy of unknown origin, especially in relation to subclassification of the lymphomas. PATIENTS AND METHODS: Consecutive patients with mediastinal and intra-abdominal lymphadenopathy of unknown origin who were referred between October 2003 and March 2005 were enrolled in the study. EUS-FNAB was carried out using a 19-gauge needle, passing through the esophageal, gastric, and duodenal walls. Pathological diagnoses were made on the basis of histological findings, including immunopathological staining. RESULTS: A total of 104 patients were included in the study. The locations of the lymph nodes were mediastinal in 50 patients, intra-abdominal in 48 patients, and both mediastinal and intra-abdominal in six patients. The diagnoses made using EUS-FNAB were lymphoma (n = 48), metastasis (n = 16), and benign/reactive (n = 40). The overall accuracy of EUS-FNAB for unknown lymphadenopathy was 98 %, and it was possible to classify the lymphomas in accordance with the World Health Organization classifications in 88 % of cases. No serious complications occurred with the procedure. CONCLUSIONS: Open thoracic surgery, laparotomy, and other invasive diagnostic procedures such as mediastinoscopy and laparoscopy can now be avoided, as EUS-FNAB is potentially a safe and accurate tool for diagnosing unknown lymphadenopathy, including lymphoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Assessment of morbidity and mortality associated with EUS-guided FNA: a systematic review
Wang, K.-X., Ben, Q.-W., Jin, Z.-D., Du, Y.-Q., Zou, D.-W., Liao, Z., & Li, Z.-S. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2010.10.045 · Cited by 439
Polkowski, M., Jenssen, C., Kaye, P., Carrara, S., Deprez, P., Gines, A., Fernández-Esparrach, G., Eisendrath, P., Aithal, G., Arcidiacono, P., et al. (2017) · Endoscopy · doi:10.1055/s-0043-119219 · Cited by 370
S3-Leitlinie „Magenkarzinom” -
Moehler, M., Al-Batran, S.-E., Andus, T., Anthuber, M., Arends, J., Arnold, D., Aust, D., Baier, P., Baretton, G., Bernhardt, J., et al. (2011) · Zeitschrift für Gastroenterologie · doi:10.1055/s-0031-1273201 · Cited by 283
Noda, Y., Fujita, N., Kobayashi, G., Itoh, K., Horaguchi, J., Takasawa, O., Obana, T., Koshita, S., Kanno, Y., Suzuki, T., et al. (2010) · Journal of Gastroenterology · doi:10.1007/s00535-010-0217-5 · Cited by 92
Metadata
- Authors
- Yasuda, I., Tsurumi, H., Omar, S., Iwashita, T., Kojima, Y., Yamada, T., Sawada, M., Takami, T., Moriwaki, H., & Soehendra, N.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2006-09
- Volume
- 38
- Issue
- 9
- Pages
- 919-924
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W1975167707
- Cited by
- 160
- References
- 0
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Endoscopic ultrasound-guided fine-needle aspiration biopsy for lymphadenopathy of unknown origin. https://app.cochat.ai/papers/10.1055/s-2006-944665
- The paper
- Yasuda, I., Tsurumi, H., Omar, S., Iwashita, T., Kojima, Y., Yamada, T., Sawada, M., Takami, T., Moriwaki, H., & Soehendra, N. (2006). Endoscopic ultrasound-guided fine-needle aspiration biopsy for lymphadenopathy of unknown origin. Endoscopy. https://doi.org/10.1055/s-2006-944665
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.