BACKGROUND AND STUDY AIMS: Population-based screening for colorectal cancer is widely recommended, with conventional colonoscopy considered to be the preferred diagnostic modality. However, compliance with screening colonoscopy is low and manpower capacity is limited. Capsule endoscopy might therefore represent a desirable alternative strategy. PATIENTS AND METHODS: The PillCam Colon capsule endoscope was prospectively tested in a multicenter setting. The indications for endoscopy in the enrolled patients included colorectal cancer screening (43 %), postpolypectomy surveillance (26 %), and lower gastrointestinal signs and symptoms (31 %). Study subjects underwent colon preparation and then ingested the capsule on the morning of the examination, with conventional colonoscopy being performed the same day. The PillCam Colon capsule findings were reviewed by three experts in capsule endoscopy who were blinded to the conventional colonoscopy findings. RESULTS: A total of 91 subjects were enrolled in three Israeli centers (55 men, 36 women; mean age 57), and the results were evaluable in 84 cases. The capsule was excreted within 10 hours in 74 % of the patients and reached the rectosigmoid colon in the other 16 %. Of the 84 evaluable patients, 20 (24 %) had significant findings, defined as at least one polyp of 6 mm or more in size or three or more polyps of any size: 14/20 (70 %) were identified with the capsule and 16/20 (80 %) were identified by conventional colonoscopy. Polyps of any size were found in 45 patients, 34/45 (76 %) found by the capsule and 36/45 (80 %) by conventional colonoscopy. In comparison with conventional colonoscopy, false-positive findings on PillCam Colon capsule examination were recorded in 15/45 cases (33 %). There were no adverse events related to the capsule endoscopy. CONCLUSIONS: PillCam Colon capsule endoscopy appears to be a promising new modality for colonic evaluation. Further improvements in the procedure will probably increase capsule examination completion and polyp detection rates. Additional studies are needed to evaluate the accuracy of PillCam Colon endoscopy in other patient populations with different prevalence levels of colonic disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2006-944832

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 340

Metadata

Authors
Eliakim, R., Fireman, Z., Gralnek, I., Yassin, K., Waterman, M., Kopelman, Y., Lachter, J., Koslowsky, B., & Adler, S.
Venue
Endoscopy
Published
2006-10-20
Volume
38
Issue
10
Pages
963-970
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2049978855
Cited by
340
References
0
FWCI
11.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the PillCam Colon capsule in the detection of colonic pathology: results of the first multicenter, prospective, comparative study. https://app.cochat.ai/papers/10.1055/s-2006-944832
The paper
Eliakim, R., Fireman, Z., Gralnek, I., Yassin, K., Waterman, M., Kopelman, Y., Lachter, J., Koslowsky, B., & Adler, S. (2006). Evaluation of the PillCam Colon capsule in the detection of colonic pathology: results of the first multicenter, prospective, comparative study. Endoscopy. https://doi.org/10.1055/s-2006-944832

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.