Hemostasis Defects Associated with Cardiac Surgery, Prosthetic Devices, and Other Extracorporeal Circuits
The DOI matches its Crossref record.
Abstract
This discussion has provided a review of the available literature regarding alterations of hemostasis associated with CPB surgery, the use of prosthetic devices, and apheresis. The key to prevention of CPB hemorrhage is to obtain an adequate preoperative workup. Of extreme importance is an adequate history with respect to bleeding tendencies and thrombotic tendencies in both the patient and the family; of equal importance is a careful history regarding the use of drugs affecting hemostasis, especially drugs known to interfere with platelet function. A careful physical examination, searching for clues of a real or potential bleeding diathesis, may also prevent catastrophic cases of hemorrhage. An adequate presurgical screen must be performed in surgical patients. In addition to the usual prothrombin time, partial thromboplastin time, and platelet count, a standardized template bleeding time (and thrombin time in patients subjected to CPB) should be performed. The use of these simple testing modalities will guard against significant defects in vascular and platelet function. Most instances of nontechnical surgical and cardiovascular surgical hemorrhage are due to several well-defined defects in hemostasis that should be readily controlled if approached in a logical manner as a team effort among surgeons, pathologists, and hematologists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thromboelastography-Guided Transfusion Algorithm Reduces Transfusions in Complex Cardiac Surgery
Shore-Lesserson, L., Manspeizer, H. E., DePerio, M., Francis, S., Vela-Cantos, F., & Ergin, M. A. (1999) · Anesthesia & Analgesia · doi:10.1097/00000539-199902000-00016 · Cited by 845
Bidstrup, B. P., Royston, D., Sapsford, R. N., Taylor, K. M., & Cosgrove, D. M. (1989) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)34573-8 · Cited by 526
Treatment with Desmopressin Acetate to Reduce Blood Loss after Cardiac Surgery
Salzman, E. W., Weinstein, M. J., Weintraub, R. M., Ware, J. A., Thurer, R. L., Robertson, L., Donovan, A., Gaffney, T., Bertele, V., Troll, J., et al. (1986) · New England Journal of Medicine · doi:10.1056/nejm198605293142202 · Cited by 504
The platelet function defect of cardiopulmonary bypass [see comments]
Kestin, A., Valeri, C., Khuri, S., Loscalzo, J., Ellis, P., MacGregor, H., Birjiniuk, V, Ouimet, H., Pasche, B., & Nelson, M. (1993) · Blood · doi:10.1182/blood.v82.1.107.bloodjournal821107 · Cited by 323
The Dose-Response Relationship of Tranexamic Acid
Horrow, J. C., Van Riper, D. F., Strong, M. D., Grunewald, K. E., & Parmet, J. L. (1995) · Anesthesiology · doi:10.1097/00000542-199502000-00009 · Cited by 300
Anticoagulation Monitoring during Cardiac Surgery: A Review of Current and Emerging Techniques
Despotis, G. J., Gravlee, G., Filos, K., Levy, J., & Fisher, D. M. (1999) · Anesthesiology · doi:10.1097/00000542-199910000-00031 · Cited by 285
Despotis, G. J., Santoro, S. A., Spitznagel, E., Kater, K. M., Cox, J. L., Barnes, P., & Lappas, D. G. (1994) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(94)70481-3 · Cited by 217
Metadata
- Authors
- Bick, R.
- Venue
- Seminars in Thrombosis and Hemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1985-07
- Volume
- 11
- Issue
- 03
- Pages
- 249-280
- ISSN
- 0094-6176 (ISSN-L)
- 1098-9064
- OpenAlex
- W1995983649
- Cited by
- 210
- References
- 0
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.