Intraoperative Evaluation of Reconstruction of the Atrio ventricular Valves by Transesophageal Echocardiography
The DOI matches its Crossref record.
Abstract
In a total of 30 operations the mitral valve was reconstructed in 18, the tricuspid valve in 11, and both AV-valves in one patient. The result of reconstruction was tested first in the open arrested heart by injection of crystalloid solution into the appropriate ventricle either through the reconstructed valve or one of the great arteries. Upon termination of cardiopulmonary bypass the valve function was examined in the beating heart by means of transesophageal contrast echocardiography (TEE). For visualization 0.5-1.0 cc of agitated Gelifundol was injected into the ventricle. In 22 patients open testing as well as echocardiographic visualization showed identical and good operative results. In 6 patients TEE revealed mild insufficiency, but no further surgery was done. In three patients with mitral valve repair, contrast-echocardiography showed severe insufficiency, which had not been detected during cardiac arrest. In these patients changes in the level of the subvalvular apparatus caused systolic dislocation of the leaflets and massive reflux. Because of these findings definive valve replacement was performed in the same operation. Intraoperative TEE is a simple, safe and reliable method für assessment of AV-valve repair, thereby motivating the surgeon towards valve preservation and improving the outcome of valve surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.536 · Cited by 3,523
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000031 · Cited by 2,905
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000029 · Cited by 2,566
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000932 · Cited by 2,449
Metadata
- Authors
- Dahm, M., Iversen, S., Schmid, F., Drexler, M., Erbel, R., & Oelert, H.
- Venue
- The Thoracic and Cardiovascular Surgeon
- Publisher
- Georg Thieme Verlag KG
- Published
- 1987-11
- Volume
- 35
- Issue
- S 2
- Pages
- 140-142
- ISSN
- 0171-6425 (ISSN-L)
- 1439-1902
- OpenAlex
- W2058948061
- Cited by
- 57
- References
- 0
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraoperative Evaluation of Reconstruction of the Atrio ventricular Valves by Transesophageal Echocardiography. https://app.cochat.ai/papers/10.1055/s-2007-1020276
- The paper
- Dahm, M., Iversen, S., Schmid, F., Drexler, M., Erbel, R., & Oelert, H. (1987). Intraoperative Evaluation of Reconstruction of the Atrio ventricular Valves by Transesophageal Echocardiography. The Thoracic and Cardiovascular Surgeon. https://doi.org/10.1055/s-2007-1020276
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.