The Validity and Accuracy of Blood Lactate Measurements for Prediction of Maximal Endurance Running Capacity
The DOI matches its Crossref record.
Abstract
The effect of using different blood lactate sampling sites in combination with different exercise test designs on the validity and accuracy for prediction of maximal endurance running velocity was investigated. Ten aerobically all-round trained firemen and nine aerobically endurance trained long-distance runners performed six differently designed treadmill running blood lactate accumulation tests. Each test consisted of five consecutive running periods on a treadmill of either 4, 6 or 8 min duration, with a mean increase in running velocity between each period of either 0.25 or 0.5 m.s-1. The corresponding treadmill running velocity to a lactate concentration of 4.0 mmol.l-1 in capillary and venous hemolysed blood and plasma for each running velocity. The mean running velocity from a maximal 12 km run for the firemen and a maximal 21 km run for the runners served as the reference of maximal endurance running velocity. There were both significant (p < 0.001) and similar relationships (r = 0.86-0.94) and no difference in mean prediction error between the predicted and measured maximal endurance running velocities with all tested protocols. However, there was a high risk of making both over- and underestimations (5% to -4%). The lowest risk of making an inaccurate prediction was found when a running duration of 8 min for each running period was used in combination with an increase in running velocity of 0.25 m.s-1, and the lactate measurements were performed in hemolysed capillary blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lactate Threshold Concepts: How Valid are They?
Faude, O., Kindermann, W., & Meyer, T. (2009) · Sports Medicine · doi:10.2165/00007256-200939060-00003 · Cited by 882
Bentley, D. J., Newell, J., & Bishop, D. (2007) · Sports Medicine · doi:10.2165/00007256-200737070-00002 · Cited by 404
The Science of Cycling: Physiology and Training ??? Part 1
Faria, E. W., Parker, D. L., & Faria, I. E. (2005) · Sports Medicine · doi:10.2165/00007256-200535040-00002 · Cited by 315
Methods to Determine Aerobic Endurance
Bosquet, L., L??ger, L., & Legros, P. (2002) · Sports Medicine · doi:10.2165/00007256-200232110-00002 · Cited by 279
The Influence of Blood Lactate Sample Site on Exercise Prescription
Moran, P., Prichard, J. G., Ansley, L., & Howatson, G. (2012) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e318225f395 · Cited by 30
“The relationship between the blood lactate response to exercise and endurance exercise performance has been extensively reported (3,11,26) and reflects the interaction of aerobic and anaerobic metabolism and the related ventilatory responses to the exercise (23).”
BackgroundEffects of varying the step duration on the determination of lactate thresholds in elite rowers
Bourdon, P. C., Woolford, S. M., & Buckley, J. D. (2018) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2017-0258 · Cited by 21
Vucetic, V., Mozek, M., & Rakovac, M. (2015) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000725 · Cited by 9
“It should, of course, be taken into account that discrepancies between studies on blood lactate concentration during postexercise recovery might be related to differences in physical fitness of the subjects, exercise protocols (14,16), the sampling procedure (14,40) and site (arterious, venous, or capillary (fingertip…”
Background
Metadata
- Authors
- Foxdal, P., Sjödin, B., Sjödin, A., & Östman, B.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1994-02
- Volume
- 15
- Issue
- 02
- Pages
- 89-95
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2318067786
- Cited by
- 53
- References
- 0
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.