Day to Day Variation in Time Trial Cycling Performance
The DOI matches its Crossref record.
Abstract
In an attempt to assess the reproducibility of laboratory cycling performance, eight well-trained (VO2max = 4.6 +/- 0.2 l.min-1) male cyclists completed 12 trials involving 4 successive performance rides at each of three total work outputs (approximately 1600, 200, and 14 kilojoules, respectively). These trials, designated as long, medium, and short trials (LT, MT, ST), represented exercise bouts of 105.12 +/- 0.41, 12.03 +/- 0.17 and 0.55 +/- 0.11 minutes, respectively. The trials, conducted on a computerized cycle ergometer in an isokinetic mode, were separated by a minimum of 72 hrs. All trials for each subject were completed at the same time of day. In all trials, subjects were allowed to select the pace in order to complete the ride in the shortest possible time. The mean coefficient of variation (CV) for performance time in each trial was: LT = +/- 1.01%, MT = +/- 0.95%, and ST = +/- 2.43%, respectively. The CV for performance time in ST was significantly greater than the CV in either LT or MT. In LT, performance time was significantly faster, and the mean % VO2max was significantly higher in trial 4 versus trials 1-3. There was no order effect in the MT or ST rides. The CV for mean VO2 (l.min-1), mean % VO2max, and RER during the LT rides were +/- 3.02%, +/- 3.64%, and +/- 3.53%, respectively. These data suggest that trained cyclists have the ability to reproduce endurance performance with a CV of approximately 1.0% in a time-trial protocol.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Laursen, P. B., & Jenkins, D. G. (2002) · Sports Medicine · doi:10.2165/00007256-200232010-00003 · Cited by 1,011
Reliability of Power in Physical Performance Tests
Hopkins, W. G., Schabort, E. J., & Hawley, J. A. (2001) · Sports Medicine · doi:10.2165/00007256-200131030-00005 · Cited by 825
Validity, Reliability and Sensitivity of Measures of Sporting Performance
Currell, K., & Jeukendrup, A. E. (2008) · Sports Medicine · doi:10.2165/00007256-200838040-00003 · Cited by 768
Design and analysis of research on sport performance enhancement
HOPKINS, W. G., HAWLEY, J. A., & BURKE, L. M. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199903000-00018 · Cited by 708
Metadata
- Authors
- Hickey, M., Costill, D., McConell, G., Widrick, J., & Tanaka, H.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1992-08
- Volume
- 13
- Issue
- 06
- Pages
- 467-470
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2067708681
- Cited by
- 92
- References
- 0
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Day to Day Variation in Time Trial Cycling Performance. https://app.cochat.ai/papers/10.1055/s-2007-1021299
- The paper
- Hickey, M., Costill, D., McConell, G., Widrick, J., & Tanaka, H. (1992). Day to Day Variation in Time Trial Cycling Performance. International Journal of Sports Medicine. https://doi.org/10.1055/s-2007-1021299
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.