Maximal Oxygen Uptake Relative to Plasma Volume Expansion
The DOI matches its Crossref record.
Abstract
Controversy exists as to whether plasma volume (PV) expansion has the potential to increase maximal oxygen uptake (VO2max). In the present study, VO2max and exercise time to fatigue were measured in nine untrained men when plasma volume (PV) was normal and then again on the next day following two levels of PV expansion. Resting PV was expanded (via intravenous infusion of a 6% dextran solution) by 282 +/- 16 ml (i.e., PVX-1) and then by 624 +/- 26 ml (i.e., PVX-2). PVX-1 increased stroke volume (CO2 rebreathing) during submaximal exercise by 15% (P less than 0.05) above normal levels. VO2max following PVX-1 was increased 4% (P less than 0.05; 3.78 to 3.92 l/min) despite a 4% reduction in hemoglobin concentration. Exercise time to fatigue was also increased (P less than 0.05). PVX-2 resulted in an 11% (P less than 0.05) reduction in hemoglobin concentration during maximal exercise and a return of VO2max and exercise time to normal levels. In summary, we have observed in untrained men that 200-300 ml of PV expansion increases SV, measured during submaximal exercise, yet causes only a small amount of hemodilution. As a result, VO2max is increased slightly and performance is improved. Further PV expansion to levels 500-600 ml above normal results in an excessive hemodilution and a subsequent decline in VO2max and performance to normal levels. There is an optimal PV for eliciting VO2max in untrained men which appears to be approximately 200-300 ml above their normal levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laursen, P. B., & Jenkins, D. G. (2002) · Sports Medicine · doi:10.2165/00007256-200232010-00003 · Cited by 1,011
Heat acclimation improves exercise performance
Lorenzo, S., Halliwill, J. R., Sawka, M. N., & Minson, C. T. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00495.2010 · Cited by 425
Models to Explain Fatigue during Prolonged Endurance Cycling
Abbiss, C. R., & Laursen, P. B. (2005) · Sports Medicine · doi:10.2165/00007256-200535100-00004 · Cited by 388
Hamouti, N., Fernández‐Elías, V. E., Ortega, J. F., & Mora‐Rodriguez, R. (2014) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12028 · Cited by 41
Urianstad, T., Villanova, S., Odden, I., Hansen, J., Mølmen, K. S., Porcelli, S., Rønnestad, B. R., & Cardinale, D. A. (2024) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00469.2024 · Cited by 19
Metadata
- Authors
- Coyle, E., Hopper, M., & Coggan, A.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1990-04
- Volume
- 11
- Issue
- 02
- Pages
- 116-119
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2057646172
- Cited by
- 100
- References
- 0
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Maximal Oxygen Uptake Relative to Plasma Volume Expansion. https://app.cochat.ai/papers/10.1055/s-2007-1024774
- The paper
- Coyle, E., Hopper, M., & Coggan, A. (1990). Maximal Oxygen Uptake Relative to Plasma Volume Expansion. International Journal of Sports Medicine. https://doi.org/10.1055/s-2007-1024774
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.