Blood Lactate Threshold Differences Between Arterialized and Venous Blood
The DOI matches its Crossref record.
Abstract
The purpose of this study was to investigate the differences between lactate thresholds determined from venous and arterialized blood. Seven endurance-trained college males performed an incremental bicycle ergometer exercise test until exhaustion. At the end of each 3 min stage, blood was sampled simultaneously from a hyperemized ear-lobe and an antecubital vein for the measurement of blood lactate (La-). Two-minute rest intervals separated each stage. Arterialized blood La-concentrations ([La-]) were significantly higher than venous blood at 350 W (14.5 and 9.7 mmol.l-1), maximal exercise (15.5 and 11.39 mmol.l-1), and throughout recovery. Arterialized [La-] was significantly higher than venous blood at the onset of blood La- accumulation (OBLA) (4.0 and 2.8 +/- 0.1 mmol.l-1), the individual anaerobic threshold (IAT) (3.4 +/- 0.3 and 2.1 +/- 0.1 mmol.l-1), and the ventilatory threshold (VT) (4.7 +/- 0.9 and 3.2 +/- 0.6 mmol.l-1). No significant differences were found between either La-threshold for arterialized or venous blood. The oxygen consumption (VO2) at OBLA was significantly lower when determined from arterialized blood La (2.3 +/- 0.2 and 2.8 +/- 0.2 l.min-1). No significant differences existed between the LT, OBLA, and IAT threshold-VO2 determinations from arterialized blood; however, significant differences were found between IAT-OBLA (2.1 +/- 0.2 and 2.8 +/- 0.2 l.min-1) and LT (2.2 +/- 0.2 l.min-1)-OBLA from venous blood. These results indicate that differences between venous and arterialized blood [La-] need to be considered when comparing different anaerobic threshold determinations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Lactate Threshold Concepts: How Valid are They?
Faude, O., Kindermann, W., & Meyer, T. (2009) · Sports Medicine · doi:10.2165/00007256-200939060-00003 · Cited by 882
Determination of the exercise intensity that elicits maximal fat oxidation
ACHTEN, J., GLEESON, M., & JEUKENDRUP, A. E. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200201000-00015 · Cited by 551
Anaerobic Threshold: The Concept and Methods of Measurement
Svedahl, K., & MacIntosh, B. R. (2003) · Canadian Journal of Applied Physiology · doi:10.1139/h03-023 · Cited by 472
Metadata
- Authors
- Robergs, R., Chwalbinska-Moneta*, J., Mitchell, J., Pascoe, D., Houmard, J., & Costill, D.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1990-12
- Volume
- 11
- Issue
- 06
- Pages
- 446-451
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2036292428
- Cited by
- 45
- References
- 0
- FWCI
- 6.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood Lactate Threshold Differences Between Arterialized and Venous Blood. https://app.cochat.ai/papers/10.1055/s-2007-1024835
- The paper
- Robergs, R., Chwalbinska-Moneta*, J., Mitchell, J., Pascoe, D., Houmard, J., & Costill, D. (1990). Blood Lactate Threshold Differences Between Arterialized and Venous Blood. International Journal of Sports Medicine. https://doi.org/10.1055/s-2007-1024835
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.