Critical Power is Related to Cycling Time Trial Performance
The DOI matches its Crossref record.
Abstract
The purpose of this study was to evaluate critical power (W(CP)) as an indicator of aerobic fitness in trained cyclists, and to determine its relationship to cycling time trial (TT) performance. Thirteen competitive USCF category 2 or 3 cyclists provided season's best 40 km TT times (mean [SD]) time = 59.6 min (3.1), and performed two 17 km TT under controlled conditions (26.6 min [1.1]). Ventilatory threshold (VT) and VO2max were determined from a maximal incremental test. W(CP) was calculated using the results of four all-out constant power tests. Mean W(CP) was 299 (61) W or 4.1 W x kg(-1), VT was 3616 (750) ml x min(-1) or 49.8 ml x kg(-1) x min(-1) (7.5), and VO2max was 4596 ml x min(-1) or 63.5 ml x kg(-1) x min(-1) (8.0). W(CP) was strongly related to VT and VO2max, demonstrating that it can serve as a measure of aerobic fitness in this population. Expressions of W(CP) were slightly to considerably more highly related to 17 km and 40 km TT performances (r = -0.77 to -0.91) than were expressions of VT and VO2max (r = -0.71 to -0.87). It is concluded that W(CP) provides an aerobic fitness measure for competitive cyclists which can be obtained without invasive testing. In addition, W(CP) is strongly related to the TT performance of competitive cyclists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laursen, P. B., & Jenkins, D. G. (2002) · Sports Medicine · doi:10.2165/00007256-200232010-00003 · Cited by 1,011
The anaerobic threshold: 50+ years of controversy
Poole, D. C., Rossiter, H. B., Brooks, G. A., & Gladden, L. B. (2021) · The Journal of Physiology · doi:10.1113/jp279963 · Cited by 312
“For instance, CP explains more than 80% of the performance variance among cyclists over 17 and 40 km time trials (Smith et al. 1999; see also Black et al. 2014; Jones & Vanhatalo, 2017).”
BackgroundThe maximal metabolic steady state: redefining the ‘gold standard’
Jones, A. M., Burnley, M., Black, M. I., Poole, D. C., & Vanhatalo, A. (2019) · Physiological Reports · doi:10.14814/phy2.14098 · Cited by 298
Methods to Determine Aerobic Endurance
Bosquet, L., L??ger, L., & Legros, P. (2002) · Sports Medicine · doi:10.2165/00007256-200232110-00002 · Cited by 279
Guidelines for animal exercise and training protocols for cardiovascular studies
Poole, D. C., Copp, S. W., Colburn, T. D., Craig, J. C., Allen, D. L., Sturek, M., O’Leary, D. S., Zucker, I. H., & Musch, T. I. (2020) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00697.2019 · Cited by 139
Metadata
- Authors
- Smith, J., Dangelmaier, B., & Hill, D.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1999-08
- Volume
- 20
- Issue
- 06
- Pages
- 374-378
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2054655755
- Cited by
- 87
- References
- 0
- FWCI
- 2.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Critical Power is Related to Cycling Time Trial Performance. https://app.cochat.ai/papers/10.1055/s-2007-971147
- The paper
- Smith, J., Dangelmaier, B., & Hill, D. (1999). Critical Power is Related to Cycling Time Trial Performance. International Journal of Sports Medicine. https://doi.org/10.1055/s-2007-971147
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.