The DOI matches its Crossref record.
The Cosmed K4 Telemetry System as an Accurate Device for Oxygen Uptake Measurements during Exercise
Open accessAbstract
The purpose of this study was to test the accuracy of oxygen uptake (VO2) measurements using the Cosmed K4 portable telemetry system. This system of higher technology than the original Cosmed K2 device, contains a CO2 electrode allowing measurements alternatively by either the Cosmed K4 system (K4) or the CPX Medical Graphics (CPX) during a maximum oxygen uptake (VO2max) ergocycle test, at rest and during several submaximal exercises (25, 50 and 75% of maximal work rate) in seven subjects. Heart rate values were comparable for exercise at the same work stage during gas collection using the two systems, indicating that the physiological stresses were similar. The VO2 values did not significantly differ at rest (4.40+/-0.83 vs 4.16+/-0.58ml x min(-1) x kg[-1]), at 25% Wmax (20.97+/-1.31 vs 21.32+/-2.54 ml x min(-1) x kg[-1]), at 50% Wmax (33.32+/-3.92 vs 33.50+/-3.51 ml x min(-1) x kg[-1]), at 75% Wmax (47.01+/-7.51 vs 47.49+/-7.11 ml x min(-1) kg[-1]) and at maximal intensities (62.07+/-8.48 vs 62.84+/-11.31 ml x min(-1) kg[-1]) using K4 and CPX devices, respectively. The results of this study indicated that the K4 system was accurate for all oxygen uptake measurements from rest to maximum exercise levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Factors affecting running economy in trained distance runners
Saunders, P. U., Pyne, D. B., Telford, R. D., & Hawley, J. A. (2004) · Sports Medicine · doi:10.2165/00007256-200434070-00005 · Cited by 975
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Powered Ankle--Foot Prosthesis Improves Walking Metabolic Economy
Au, S. K., Weber, J., & Herr, H. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2008747 · Cited by 487
A QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427
Metadata
- Authors
- Hausswirth, C., Bigard, A., & Le Chevalier, J.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1997-08
- Volume
- 28
- Issue
- 06
- Pages
- 449-453
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W1980557142
- Cited by
- 193
- References
- 0
- FWCI
- 5.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Cosmed K4 Telemetry System as an Accurate Device for Oxygen Uptake Measurements during Exercise. https://app.cochat.ai/papers/10.1055/s-2007-972662
- The paper
- Hausswirth, C., Bigard, A., & Le Chevalier, J. (1997). The Cosmed K4 Telemetry System as an Accurate Device for Oxygen Uptake Measurements during Exercise. International Journal of Sports Medicine. https://doi.org/10.1055/s-2007-972662
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.