Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 163

The DOI matches its Crossref record.

Assessment of the Reproducibility of Performance Testing on an Air-Braked Cycle Ergometer

Palmer, G., Dennis, S., Noakes, T., Hawley, J. · 1996 · International Journal of Sports Medicine

Abstract

The purposes of this study were (I) to assess the reproducibility of endurance performance testing on an air-braked cycle ergometer, and (II) to compare laboratory performances to performances in road races. Ten well-trained, competitive cyclists (peak power output [PPO] 443 +/- 37 W, [values are mean +/- SD]) undertook either: (I) three 20 km and three 40 km time trials (TT) on an air braked ergometry system (Kingcycle) (n = 6), and/or (II) three 40 km laboratory TT and two 40 km road TT competitions (n = 8). The time taken for the laboratory simulated 20 km and 40 km TT rides were highly reproducible (coefficient of variation 1.1 +/- 0.9% and 1.0 +/- 0.5%, respectively). However, the mean power output and heart rate were significantly different (p < 0.0001) between the 20 km and 40 km TT (327.5 +/- 16.9 vs 303.9 +/- 14.9 W and 171.4 +/- 5.1 vs 168.3 +/- 4.4 beats/min, respectively). A strong relationship (r = 0.99, p < 0.001) was observed between the mean cycling time and the average sustained power output. A significant correlation (r = 0.98, p < 0.001) was also observed between laboratory and road race times, although road race times were, on average, some 8% slower. These findings indicate that the Kingcycle ergometry system can be used as a reliable method of assessing short term endurance cycling performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2007-972849

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 163

Metadata

Authors
Palmer, G., Dennis, S., Noakes, T., & Hawley, J.
Venue
International Journal of Sports Medicine
Published
1996-05
Volume
17
Issue
04
Pages
293-298
ISSN
  • 0172-4622 (ISSN-L)
  • 1439-3964
OpenAlex
W2001193060
Cited by
163
References
0
FWCI
7.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of the Reproducibility of Performance Testing on an Air-Braked Cycle Ergometer. https://app.cochat.ai/papers/10.1055/s-2007-972849
The paper
Palmer, G., Dennis, S., Noakes, T., & Hawley, J. (1996). Assessment of the Reproducibility of Performance Testing on an Air-Braked Cycle Ergometer. International Journal of Sports Medicine. https://doi.org/10.1055/s-2007-972849

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.