The DOI matches its Crossref record.
Assessment of the Reproducibility of Performance Testing on an Air-Braked Cycle Ergometer
Abstract
The purposes of this study were (I) to assess the reproducibility of endurance performance testing on an air-braked cycle ergometer, and (II) to compare laboratory performances to performances in road races. Ten well-trained, competitive cyclists (peak power output [PPO] 443 +/- 37 W, [values are mean +/- SD]) undertook either: (I) three 20 km and three 40 km time trials (TT) on an air braked ergometry system (Kingcycle) (n = 6), and/or (II) three 40 km laboratory TT and two 40 km road TT competitions (n = 8). The time taken for the laboratory simulated 20 km and 40 km TT rides were highly reproducible (coefficient of variation 1.1 +/- 0.9% and 1.0 +/- 0.5%, respectively). However, the mean power output and heart rate were significantly different (p < 0.0001) between the 20 km and 40 km TT (327.5 +/- 16.9 vs 303.9 +/- 14.9 W and 171.4 +/- 5.1 vs 168.3 +/- 4.4 beats/min, respectively). A strong relationship (r = 0.99, p < 0.001) was observed between the mean cycling time and the average sustained power output. A significant correlation (r = 0.98, p < 0.001) was also observed between laboratory and road race times, although road race times were, on average, some 8% slower. These findings indicate that the Kingcycle ergometry system can be used as a reliable method of assessing short term endurance cycling performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reliability of Power in Physical Performance Tests
Hopkins, W. G., Schabort, E. J., & Hawley, J. A. (2001) · Sports Medicine · doi:10.2165/00007256-200131030-00005 · Cited by 825
Self-citationValidity, Reliability and Sensitivity of Measures of Sporting Performance
Currell, K., & Jeukendrup, A. E. (2008) · Sports Medicine · doi:10.2165/00007256-200838040-00003 · Cited by 768
Design and analysis of research on sport performance enhancement
HOPKINS, W. G., HAWLEY, J. A., & BURKE, L. M. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199903000-00018 · Cited by 708
Self-citationThe bioenergetics of world class cycling
Jeukendrup, A. E., Craig, N. P., & Hawley, J. A. (2000) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(00)80008-0 · Cited by 411
Self-citationAcute Dietary Nitrate Supplementation Improves Cycling Time Trial Performance
LANSLEY, K. E., WINYARD, P. G., BAILEY, S. J., VANHATALO, A., WILKERSON, D. P., BLACKWELL, J. R., GILCHRIST, M., BENJAMIN, N., & JONES, A. M. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821597b4 · Cited by 388
Metadata
- Authors
- Palmer, G., Dennis, S., Noakes, T., & Hawley, J.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1996-05
- Volume
- 17
- Issue
- 04
- Pages
- 293-298
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2001193060
- Cited by
- 163
- References
- 0
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of the Reproducibility of Performance Testing on an Air-Braked Cycle Ergometer. https://app.cochat.ai/papers/10.1055/s-2007-972849
- The paper
- Palmer, G., Dennis, S., Noakes, T., & Hawley, J. (1996). Assessment of the Reproducibility of Performance Testing on an Air-Braked Cycle Ergometer. International Journal of Sports Medicine. https://doi.org/10.1055/s-2007-972849
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.