CoChat

Dynamic Pituitary MRI has High Sensitivity and Specificity for the Diagnosis of Mild Cushing's Syndrome and should be Part of the Initial Workup

Friedman, T., Zuckerbraun, E., Lee, M., Kabil, M., Shahinian, H. · 2007 · Hormone and Metabolic Research
Cited by 90

The DOI matches its Crossref record.

Abstract

AIM: The diagnosis of mild or episodic Cushing's syndrome is difficult. The standard tests include 24-hour urinary free cortisol (UFC), night-time blood, or salivary cortisol measurements, and dexamethasone suppression tests. Imaging studies of the pituitary have not been recommended as part of the initial workup (only to help distinguish pituitary Cushing's disease from the ectopic ACTH syndrome) because of poor sensitivity and specificity. With the development of dynamic pituitary MRI which uses multiple coronal dynamic sequences following gadolinium intravenous contrast, we hypothesized that the sensitivity and specificity would be increased and MRI would provide useful information for the initial diagnosis of Cushing's syndrome. METHODS: This was a retrospective chart review examining charts from 87 consecutive patients who were evaluated for Cushing's syndrome in a tertiary Endocrinology clinic over a one-year period. Most patients had mild and/or episodic hypercortisolism. Of these patients, 24 eventually were diagnosed with pituitary Cushing's syndrome by biochemical testing (24-h UFC and urinary 17-hydroxycorticosteroids, 11 PM salivary cortisol measurements, evening plasma cortisol), and 22 had the diagnosis of Cushing's syndrome excluded. Dynamic pituitary MRI (1.5 Tesla) was performed on all patients. The reader of the MRI was blind to the diagnosis. RESULTS: Twenty-three of 24 patients had a MRI consistent with a pituitary lesion (21 with a microadenoma, two with pituitary asymmetry). In contrast, only 3 of 20 patients (2 patient did not have MRIs) in the Cushing's excluded group had a pituitary lesion on dynamic MRI. Dynamic pituitary MRI had the highest sensitivity and negative predictive value of any testing modalities and its specificity and positive predictive value were similar to that of other tests. CONCLUSION: We conclude that almost all patients in this series with Cushing's syndrome have a lesion on dynamic pituitary MRI, a rate much higher than the 50-60% rate reported for non-dynamic MRIs. The false positive rate of 16% in our group of Cushing's excluded patients is similar to the literature value of 10% seen in normal volunteers and is acceptable since MRI is not used solely as a determinant for the diagnosis. While a negative MRI will miss those patients with adrenal or ectopic Cushing's syndrome, those patients can usually be diagnosed by other testing. Thus this preliminary study implies that dynamic pituitary MRI adds valuable information to assist in the diagnosis of Cushing's syndrome and should be ordered as part of the initial workup.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2007-980192

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 90

Metadata

Authors
Friedman, T., Zuckerbraun, E., Lee, M., Kabil, M., & Shahinian, H.
Venue
Hormone and Metabolic Research
Published
2007-06
Volume
39
Issue
6
Pages
451-456
ISSN
  • 0018-5043 (ISSN-L)
  • 1439-4286
OpenAlex
W1986971746
Cited by
90
References
0
FWCI
3.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamic Pituitary MRI has High Sensitivity and Specificity for the Diagnosis of Mild Cushing's Syndrome and should be Part of the Initial Workup. https://app.cochat.ai/papers/10.1055/s-2007-980192
The paper
Friedman, T., Zuckerbraun, E., Lee, M., Kabil, M., & Shahinian, H. (2007). Dynamic Pituitary MRI has High Sensitivity and Specificity for the Diagnosis of Mild Cushing's Syndrome and should be Part of the Initial Workup. Hormone and Metabolic Research. https://doi.org/10.1055/s-2007-980192

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.