CoChat

Umbilical Arterial Catheter Use: Report of an Audit Conducted by the Study Group for Complications of Perinatal Care

Fletcher, Mary, Brown, David, Landers, Susan, Seguin, John · 1994 · American Journal of Perinatology
Cited by 54

The DOI matches its Crossref record.

Abstract

The Study Group for Complications of Perinatal Care through 13 of its participating neonatal intensive care units conducted an audit of umbilical artery catheter (UAC) use over 3 months. Of 1941 patient admissions, 582 (30%) had a UAC inserted and left in place for a mean of 4.9 days. The mean supplemental oxygen concentration (FIO2) at removal was 0.35 with over 55% of UACs remaining in place until FIO2 was less than 0.26. Institutional practices varied widely for positioning the catheter tip, use of heparin, and types of infusates, as did the frequency of adverse events that prompted removal of the UAC. Most institutions with multiple physicians found less consistency in practice patterns within their own units than presumed prior to the audit. Just two institutions preferred catheter placement in the abdominal aorta (low) with the others selecting a low site only after detecting a malposition below the initially sought thoracic level. All but one group routinely used heparin, although in varying concentrations and total doses. Patient weight and catheter duration were inversely correlated, with smaller patients having catheters left in place for significantly longer periods (P < 0.01). Similarly, smaller patients had a higher likelihood of catheter removal because of an adverse event; the adverse events were not necessarily related to longer duration. A significant relationship existed between positioning a catheter tip in the abdominal aorta and removal for adverse events (P < 0.05).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2007-994564

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 54

Metadata

Authors
Fletcher, M., Brown, D., Landers, S., & Seguin, J.
Venue
American Journal of Perinatology
Published
1994-03
Volume
11
Issue
02
Pages
94-99
ISSN
  • 0735-1631 (ISSN-L)
  • 1098-8785
OpenAlex
W2034264415
Cited by
54
References
0
FWCI
0.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Umbilical Arterial Catheter Use: Report of an Audit Conducted by the Study Group for Complications of Perinatal Care. https://app.cochat.ai/papers/10.1055/s-2007-994564
The paper
Fletcher, M., Brown, D., Landers, S., & Seguin, J. (1994). Umbilical Arterial Catheter Use: Report of an Audit Conducted by the Study Group for Complications of Perinatal Care. American Journal of Perinatology. https://doi.org/10.1055/s-2007-994564

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.