The DOI matches its Crossref record.
In Vivo Registration of Achilles Tendon Forces in Man
Abstract
Mechanical behavior of muscle and its control is largely unknown under normal movement conditions. The present report deals with the methodological development to record directly in vivo forces from the human achilles tendon (AT) when the subjects perform normal movements ranging from slow walking to maximal sprinting and jumping. The development began with animal experiments, which dealt with the transducer design, surgical operation procedures, and duration of implantation. The first human experiment utilized an E form transducer implanted around the AT under local anesthesia. The transducer was kept in situ for 7 days, and on the 8th day recordings were made on simple plantar flexion movements and during slow walking. Further development led to final selection of a "buckle"-type transducer, and the measurements can be made immediately after operation and they usually last 2-3 h. The AT transducer can be calibrated by placing the subject in a prone position on to a calibration table. His operated foot was placed in a special shoe, the axis of which coincided with that of the ankle joint. A pulley system with known weights was used to dorsiflex the foot. Taking into consideration the geometrical arrangement of the AT transducer, axis of rotation, and the pulley system, the exact values of AT forces could be calculated. The actual measurements incorporate the use of EMG recordings of the leg extensor muscles and various external force measurements, such as long force platform or oscillating ergometers. The transducer is removed immediately after the measurements and the subjects recover.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
TENDON INJURY AND TENDINOPATHY: HEALING AND REPAIR
SHARMA, P., & MAFFULLI, N. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200501000-00030 · Cited by 1,074
Stretch-shortening cycle: a powerful model to study normal and fatigued muscle
Komi, P. V. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00064-6 · Cited by 975
Self-citationBiomechanics of Sprint Running: A Review
Mero, A., Komi, P. V., & Gregor, R. J. (1992) · Sports Medicine · doi:10.2165/00007256-199213060-00002 · Cited by 665
Self-citationAchilles Tendon Injuries in Athletes
Kvist, M. (1994) · Sports Medicine · doi:10.2165/00007256-199418030-00004 · Cited by 571
Patellar tendinopathy: some aspects of basic science and clinical management.
Khan, K. M., Maffulli, N., Coleman, B. D., Cook, J. L., & Taunton, J. E. (1998) · British Journal of Sports Medicine · doi:10.1136/bjsm.32.4.346 · Cited by 510
Metadata
- Authors
- Komi, P., Salonen, M., Järvinen, M., & Kokko, O.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1987-03
- Volume
- 08
- Issue
- S 1
- Pages
- S3-S8
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2415692703
- Cited by
- 159
- References
- 0
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo Registration of Achilles Tendon Forces in Man. https://app.cochat.ai/papers/10.1055/s-2008-1025697
- The paper
- Komi, P., Salonen, M., Järvinen, M., & Kokko, O. (1987). In Vivo Registration of Achilles Tendon Forces in Man. International Journal of Sports Medicine. https://doi.org/10.1055/s-2008-1025697
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.