Does the Gas Exchange Anaerobic Threshold Occur at a Fixed Blood Lactate Concentration of 2 or 4 m M?
The DOI matches its Crossref record.
Abstract
The anaerobic threshold (theta an) is defined as the VO2 at which blood lactate concentration [lactate] begins to systematically increase (lactate "break point") during incremental exercise. Numerous studies have shown that gas exchange break points at the anaerobic threshold correlate highly (r congruent to 0.90) with the lactate break point. Recently, it has been suggested that the anaerobic threshold occurs at a fixed [lactate] of 2 mM or 4 mM. We therefore compared the gas exchange theta an to the three lactate criteria (break point, 2 mM, and 4 mM) for theta an estimation. Fourteen subjects performed an incremental cycle ergometer test. Ventilation and gas exchange were computed every 30 s. During the same 30-s intervals, venous blood was sampled for [lactate]. Four criteria were used for theta an determination: (1) systematic increase in VE/VO2, without a concomitant increase in VE/VCO2; (2) lactate break point; (3) 2 mM [lactate]; and (4) 4 mM [lactate]. Relative to the gas exchange criterion (i.e., #1), theta an was higher by 44, 280, and 1028 ml X min-1 for the three lactate criteria, respectively; the last two being significantly different (P less than 0.05). Thus, the anaerobic threshold discerned from gas exchange or the lactate break point does not correspond with a fixed, absolute [lactate] of 2 mM or 4 mM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Binder, R. K., Wonisch, M., Corra, U., Cohen-Solal, A., Vanhees, L., Saner, H., & Schmid, J.-P. (2008) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e328304fed4 · Cited by 487
Lactate metabolism: historical context, prior misinterpretations, and current understanding
Ferguson, B. S., Rogatzki, M. J., Goodwin, M. L., Kane, D. A., Rightmire, Z., & Gladden, L. B. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3795-6 · Cited by 441
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
Bentley, D. J., Newell, J., & Bishop, D. (2007) · Sports Medicine · doi:10.2165/00007256-200737070-00002 · Cited by 404
Methods to Determine Aerobic Endurance
Bosquet, L., L??ger, L., & Legros, P. (2002) · Sports Medicine · doi:10.2165/00007256-200232110-00002 · Cited by 279
Mcnaughton, L. (1987) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1987.10605458 · Cited by 27
Metadata
- Authors
- Davis, J., Caiozzo, V., Lamarra, N., Ellis, J., Vandagriff, R., Prietto, C., & McMaster, W.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1983-05
- Volume
- 04
- Issue
- 02
- Pages
- 89-93
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W1967721119
- Cited by
- 46
- References
- 0
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.