CoChat

Artificial Intelligence–Powered Rapid Identification of ST-Elevation Myocardial Infarction via Electrocardiogram (ARISE) — A Pragmatic Randomized Controlled Trial

Lin, Chin, Liu, Wei-Ting, Chang, Chiao-Hsiang, Lee, Chiao-Chin, Hsing, Shi-Chue, Fang, Wen-Hui, Tsai, Dung-Jang, Chen, Kai-Chieh, Lee, Chun-Ho, Cheng, Cheng-Chung, Hung, Yi-Jen, Lin, Shih-Hua, Tsai, Chien-Sung, Lin, Chin-Sheng · 2024 · NEJM AI
Cited by 54

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BackgroundTimely diagnosis of ST-elevation myocardial infarction (STEMI) is crucial for the treatment of patients with acute coronary syndrome. Artificial intelligence–enabled electrocardiogram (AI-ECG) has shown potential for the accurate and timely detection of STEMI on 12-lead electrocardiograms (ECGs). However, its impact on clinical treatment times is unknown.MethodsTo evaluate the potential of AI-ECG–assisted detection of STEMI to reduce treatment delays for patients with STEMI, we conducted an open-label, cluster randomized controlled trial involving 43,234 eligible patients (mean age, 60 years; 49.5% male) without a history of coronary angiography within 3 days in the emergency department or inpatient wards at Tri-Service General Hospital, Taipei, Taiwan between May 1, 2022, and April 31, 2023. Patients were randomly assigned 1:1 to AI-ECG–assisted detection of STEMI (intervention group) or to standard of care (control group). The primary end point was door-to-balloon time; ECG-to-balloon time was also evaluated as a branch of the primary analysis. Secondary end points included incidence of new-onset low ejection fraction, cardiac death, and all-cause mortality.ResultsAmong the 43,234 patients, 77 in the intervention group and 68 in the control group were diagnosed with STEMI with occluded vessel(s) based on coronary angiography. The use of AI-ECG demonstrated a positive predictive value of 89.5% (95% confidence interval [CI], 85.3 to 93.6%) and a negative predictive value of 99.9% (95% CI, 99.9 to 100.0%). For patients in the emergency department, the median door-to-balloon time was 82.0 minutes (interquartile range, 62.5 to 89.5) in the intervention group compared with 96.0 minutes (interquartile range, 78.0 to 137.0) in the control group (P=0.002). When analyzing both emergency and inpatient cases, the median ECG-to-balloon time was 78.0 minutes (interquartile range, 56.9 to 88.2 minutes) in the intervention group compared with 83.6 minutes (interquartile range, 72.7 to 127.8 minutes) in the control group (P=0.011). In the intervention group versus the control group, there were 340 versus 304 cases, respectively, of new-onset heart failure with reduced ejection fraction (odds ratio, 1.12; P=0.151), 85 versus 116 cases of cardiac death (odds ratio, 0.73; P=0.029), and 1153 versus 1127 cases of all-cause mortality (odds ratio, 1.02; P=0.568).ConclusionsIn patients with STEMI, AI-ECG–assisted triage of STEMI decreased the door-to-balloon time for patients presenting to the emergency department and decreased the ECG-to-balloon time for patients in the emergency room and inpatients. (Funded by the National Science and Technology Council, Taiwan and others; ClinicalTrials.gov number, NCT05118009.)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/aioa2400190

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 54

Metadata

Authors
Lin, C., Liu, W.-T., Chang, C.-H., Lee, C.-C., Hsing, S.-C., Fang, W.-H., Tsai, D.-J., Chen, K.-C., Lee, C.-H., Cheng, C.-C., Hung, Y.-J., Lin, S.-H., Tsai, C.-S., & Lin, C.-S.
Venue
NEJM AI
Published
2024-06-27
Volume
1
Issue
7
ISSN
2836-9386 (ISSN-L)
OpenAlex
W4400087060
Cited by
54
References
8
FWCI
14.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.