The DOI matches its Crossref record.
Pulmonary Complications of the Flow-Directed Balloon-Tipped Catheter
Abstract
Retrospective analysis of the course of 125 patients in whom flow-directed balloon-tipped catheters were employed showed that in nine (7.2 per cent), pulmonary ischemic lesions appeared to have occurred as a direct result of the use of the catheter. Mechanisms of the pulmonary ischemia included persistent wedging of the catheter tip in a peripheral artery (six cases), obstruction of a more central pulmonary artery by an inflated balloon (one case), and pulmonary embolism from venous thrombosis developing around the catheter (two cases). Awareness of the tendency for spontaneous wedging of the catheter to occur and of the possibility of air remaining in the balloon after use should reduce the frequency of these complications. (N Engl J Med 290:927–931, 1974)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Connors, A. F., McCaffree, D. R., & Gray, B. A. (1983) · New England Journal of Medicine · doi:10.1056/nejm198302033080508 · Cited by 365
Complications of Pulmonary Artery Catheterization in the Care of Critically III Patients
Elliott, C. G., Zimmerman, G. A., & Clemmer, T. P. (1979) · Chest · doi:10.1378/chest.76.6.647 · Cited by 265
Metadata
- Authors
- Foote, G. A., Schabel, S. I., & Hodges, M.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1974-04-25
- Volume
- 290
- Issue
- 17
- Pages
- 927-931
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2337101953
- Cited by
- 234
- References
- 0
- FWCI
- 13.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulmonary Complications of the Flow-Directed Balloon-Tipped Catheter. https://app.cochat.ai/papers/10.1056/nejm197404252901702
- The paper
- Foote, G. A., Schabel, S. I., & Hodges, M. (1974). Pulmonary Complications of the Flow-Directed Balloon-Tipped Catheter. New England Journal of Medicine. https://doi.org/10.1056/nejm197404252901702
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.