The DOI matches its Crossref record.
Nonoperative Dilatation of Coronary-Artery Stenosis: Percutaneous Transluminal Coronary Angioplasty
Abstract
In percutaneous transluminal coronary angioplasty, a catheter system is introduced through a systemic artery under local anesthesia to dilate a stenotic artery by controlled inflation of a distensible balloon. Over the past 18 months, we have used this technic in 50 patients. The technic was successful in 32 patients, reducing the stenosis from a mean of 84 to 34 per cent (P less than 0.001) and the coronary-pressure gradient from a mean of 58 to 19 mm Hg (P less than 0.001). Twenty-nine patients showed improvement in cardiac function during follow-up examination. Because of acute deterioration in clinical status, emergency bypass was later necessary in five patients; three showed electrocardiographic evidence of infarcts. Patients with single-vessel disease appear to be most suitable for the procedure, and a short history of pain indicates the presence of a soft (distensible) atheroma likely to respond to dilatation. We estimate that only about 10 to 15 per cent of candidates for bypass surgery have lesions suitable for this procedure. A prospective randomized trial will be necessary to evaluate its usefulness in comparison with surgical and medical management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fuster, V (1994) · Circulation · doi:10.1161/01.cir.90.4.2126 · Cited by 848
Smith, S. C., Dove, J. T., Jacobs, A. K., Kennedy, J. W., Kereiakes, D., Kern, M. J., Kuntz, R. E., Popma, J. J., Schaff, H. V., Williams, D. O., et al. (2001) · Circulation · doi:10.1161/01.cir.103.24.3019 · Cited by 608
Targeting mammalian target of rapamycin (mTOR) for health and diseases
Tsang, C. K., Qi, H., Liu, L. F., & Zheng, X. F. S. (2007) · Drug Discovery Today · doi:10.1016/j.drudis.2006.12.008 · Cited by 406
Exercise training intervention after coronary angioplasty: the ETICA trial
Belardinelli, R., Paolini, I., Cianci, G., Piva, R., Georgiou, D., & Purcaro, A. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01236-0 · Cited by 342
Takenaka, S., Nakamura, N., Shiode, N., Shirota, K., Suyama, H., Goto, Y., Hirao, H., Nakazawa, Y., Inoue, K., & Nagamatsu, T. (2003) · Japanese Heart Journal · doi:10.1536/jhj.44.31 · Cited by 3
Metadata
- Authors
- Grüntzig, A. R., Senning, Å., & Siegenthaler, W. E.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1979-07-12
- Volume
- 301
- Issue
- 2
- Pages
- 61-68
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W1989456091
- Cited by
- 2,419
- References
- 0
- FWCI
- 84.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nonoperative Dilatation of Coronary-Artery Stenosis: Percutaneous Transluminal Coronary Angioplasty. https://app.cochat.ai/papers/10.1056/nejm197907123010201
- The paper
- Grüntzig, A. R., Senning, Å., & Siegenthaler, W. E. (1979). Nonoperative Dilatation of Coronary-Artery Stenosis: Percutaneous Transluminal Coronary Angioplasty. New England Journal of Medicine. https://doi.org/10.1056/nejm197907123010201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.