The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Real-Time Ultrasonography: Diagnostic Technique of Choice in Calculous Gallbladder Disease
Abstract
We used high-resolution real-time ultrasonography to examine the gallbladder in patients with signs and symptoms suggestive of gallbladder disease. Using this noninvasive technique, the physician can examine the gallbladder and related anatomy thoroughly in less than five minutes. The technique is much easier to learn and perform than gray-scale ultrasonography. In 313 patients in whom gallstones were later confirmed at cholecystectomy or autopsy, the ultrasound examination achieved an accuracy of 96 per cent in the evaluation of cholelithiasis. Five examinations gave false-negative results, one a definite false-positive result, and two possible false-positive results; six examinations were inadequate. The sensitivity of the method was 98 per cent, and the specificity was between 93.5 and 97.7 per cent. In 124 patients evaluated prospectively by means of both ultrasound and oral cholecystography, the ultrasound study revealed calculi in five patients in whom calculi were not demonstrated on an adequate oral cholecystogram. No calculus detected with oral cholecystography was missed by ultrasound. We believe that ultrasound should replace oral cholecystography as the first technique in evaluation of the patient with suspected gallbladder disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gray Scale Ultrasonic Cholecystography: A Comparison with Conventional Radiographic Techniques
Leopold, G. R., Amberg, J. R., Gosink, B. B., & Mittelstaedt, C. A. (1976) · Radiology · doi:10.1148/121.2.445 · Cited by 133
Cited by
A population study on the prevalence of gallstone disease: The sirmione study
Barbara, L., Sama, C., Labate, A. M. M., Taroni, F., Rusticali, A. G., Festi, D., Sapio, C., Roda, E., Banterle, C., Puci, A., et al. (1987) · Hepatology · doi:10.1002/hep.1840070520 · Cited by 549
Revised Estimates of Diagnostic Test Sensitivity and Specificity in Suspected Biliary Tract Disease
Shea, J. A. (1994) · Archives of Internal Medicine · doi:10.1001/archinte.154.22.2573 · Cited by 342
Gallbladder disease in the morbidly obese
Amaral, J. F., & Thompson, W. R. (1985) · The American Journal of Surgery · doi:10.1016/s0002-9610(85)80055-6 · Cited by 153
Insulin Resistance Causes Human Gallbladder Dysmotility
Nakeeb, A., Comuzzie, A. G., Al-Azzawi, H., Sonnenberg, G. E., Kissebah, A. H., & Pitt, H. A. (2006) · Journal of Gastrointestinal Surgery · doi:10.1016/j.gassur.2006.04.005 · Cited by 84
Hood, K. A., Gleeson, D., Ruppin, D. C., & Dowling, R. H. (1993) · Gut · doi:10.1136/gut.34.9.1277 · Cited by 34
Metadata
- Authors
- Cooperberg, P. L., & Burhenne, H. J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1980-06-05
- Volume
- 302
- Issue
- 23
- Pages
- 1277-1279
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W1971781961
- Cited by
- 277
- References
- 1
- FWCI
- 21.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Ultrasonography: Diagnostic Technique of Choice in Calculous Gallbladder Disease. https://app.cochat.ai/papers/10.1056/nejm198006053022303
- The paper
- Cooperberg, P. L., & Burhenne, H. J. (1980). Real-Time Ultrasonography: Diagnostic Technique of Choice in Calculous Gallbladder Disease. New England Journal of Medicine. https://doi.org/10.1056/nejm198006053022303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.