The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Accuracy of the Ventricular Tachycardia-Induction Study for Predicting Long-Term Efficacy and Inefficacy of Antiarrhythmic Drugs
Abstract
We evaluated the prophylactic effect of antiarrhythmic agents against induction of ventricular tachycardia by extrastimulation in 51 patients with recurrent ventricular tachycardia. These patients subsequently underwent 58 long-term trials with tested agents. In 39 trials an agent predicted to be effective by electrophysiologic study was administered, and in 19 a drug predicted to be ineffective was used. There were no clinical differences between the two treatment groups. During a mean follow-up period of 8.2 months, arrhythmias recurred significantly less frequently in the group treated with drugs predicted to be effective than in the other group (P < 0.001); at six months 80 per cent of the patients in the former group were successfully treated, as compared with 33 per cent in the latter group. At 18 months the corresponding figures were 68 per cent and 11 per cent. We conclude that the arrhythmia-induction technique accurately predicts the clinical effectiveness of drugs used in the long-term treatment of recurrent ventricular tachycardia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum utilization of the life table method in analyzing survival
Cutler, S. J., & Ederer, F. (1958) · Journal of Chronic Diseases · doi:10.1016/0021-9681(58)90126-7 · Cited by 2,870
Horowitz, L. N., Josephson, M. E., Farshidi, A., Spielman, S. R., Michelson, E. L., & Greenspan, A. M. (1978) · Circulation · doi:10.1161/01.cir.58.6.986 · Cited by 605
Mason, J. W., & Winkle, R. A. (1978) · Circulation · doi:10.1161/01.cir.58.6.971 · Cited by 525
Self-citationFisher, J. D., Cohen, H. L., Mehra, R., Altschuler, H., Escher, D. J. W., & Furman, S. (1977) · American Heart Journal · doi:10.1016/s0002-8703(77)80018-5 · Cited by 353
Classification of antiarrhythmic drugs
Vaughan, Williams, & Em (1975) · Medical Entomology and Zoology · Cited by 347
Cited by
Determinants of Survival in Patients with Ventricular Tachyarrhythmias
Swerdlow, C. D., Winkle, R. A., & Mason, J. W. (1983) · New England Journal of Medicine · doi:10.1056/nejm198306163082402 · Cited by 509
Self-citationMaron, B. J., Savage, D. D., Wolfson, J. K., & Epstein, S. E. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90604-4 · Cited by 495
Guidelines for implantation of cardiac pacemakers and antiarrhythmia devices
Forcinito, M. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80209-8 · Cited by 399
Randomized antiarrhythmic drug therapy in survivors of cardiac arrest (the CASCADE study)
The CASCADE Investigators (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90673-z · Cited by 308
Olshansky, B., Mazuz, M., & Martins, J. B. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80040-1 · Cited by 125
Metadata
- Authors
- Mason, J. W., & Winkle, R. A.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1980-11-06
- Volume
- 303
- Issue
- 19
- Pages
- 1073-1077
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2342098126
- Cited by
- 360
- References
- 5
- FWCI
- 28.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of the Ventricular Tachycardia-Induction Study for Predicting Long-Term Efficacy and Inefficacy of Antiarrhythmic Drugs. https://app.cochat.ai/papers/10.1056/nejm198011063031901
- The paper
- Mason, J. W., & Winkle, R. A. (1980). Accuracy of the Ventricular Tachycardia-Induction Study for Predicting Long-Term Efficacy and Inefficacy of Antiarrhythmic Drugs. New England Journal of Medicine. https://doi.org/10.1056/nejm198011063031901
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.