The DOI matches its Crossref record.
Ventricular Defibrillation — A Comparative Trial Using 175-J and 320-J Shocks
Abstract
We compared the effects of initial electrical shocks using 175 and 320 J (joules) in 249 patients with ventricular fibrillation. Survival was unrelated to the energy level used for defibrillation. Reversion to an organized rhythm occurred in a similar proportion of both treatment groups after one or two shocks. The rhythm identified after the first shock was related to outcome (the survival rate was 42 per cent in patients with supraventricular rhythm, 30 per cent in persistent ventricular fibrillation, 26 per cent in idioventricular rhythm, and 14 per cent in asystole; P less than 0.02). Fibrillation recurred in 68 per cent of patients who had been initially defibrillated to an organized rhythm. Repeated shocks at the higher energy level resulted in a higher incidence of atrioventricular block after defibrillation (24 per cent of patients receiving 320 J and 9 per cent of those receiving shocks of lower energy; P less than 0.005). Patients who survived required fewer shocks than patients who later died in the hospital (2.6 shocks as compared with 3.6; P less than 0.005). We conclude that initial defibrillatory shocks using 175 J are as safe and effective as shocks of nearly twice that energy level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Peberdy, M. A., Callaway, C. W., Neumar, R. W., Geocadin, R. G., Zimmerman, J. L., Donnino, M., Gabrielli, A., Silvers, S. M., Zaritsky, A. L., Merchant, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971002 · Cited by 2,522
Prognostic Importance of Defibrillator Shocks in Patients with Heart Failure
Poole, J. E., Johnson, G. W., Hellkamp, A. S., Anderson, J., Callans, D. J., Raitt, M. H., Reddy, R. K., Marchlinski, F. E., Yee, R., Guarnieri, T., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa071098 · Cited by 1,462
European Resuscitation Council Guidelines for Resuscitation 2005
Soar, J., Deakin, C. D., Nolan, J. P., Abbas, G., Alfonzo, A., Handley, A. J., Lockey, D., Perkins, G. D., & Thies, K. (2005) · Resuscitation · doi:10.1016/j.resuscitation.2005.10.004 · Cited by 832
Nichol, G., Stiell, I. G., Laupacis, A., Pham, B., Maio, V. J. D., & Wells, G. A. (1999) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(99)80054-7 · Cited by 301
Qin, H., Walcott, G. P., Killingsworth, C. R., Rollins, D. L., Smith, W. M., & Ideker, R. E. (2002) · Circulation · doi:10.1161/01.cir.0000016702.86180.f6 · Cited by 61
Metadata
- Authors
- Weaver, W. D., Cobb, L. A., Copass, M. K., & Hallstrom, A. P.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1982-10-28
- Volume
- 307
- Issue
- 18
- Pages
- 1101-1106
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2031367112
- Cited by
- 233
- References
- 0
- FWCI
- 20.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ventricular Defibrillation — A Comparative Trial Using 175-J and 320-J Shocks. https://app.cochat.ai/papers/10.1056/nejm198210283071801
- The paper
- Weaver, W. D., Cobb, L. A., Copass, M. K., & Hallstrom, A. P. (1982). Ventricular Defibrillation — A Comparative Trial Using 175-J and 320-J Shocks. New England Journal of Medicine. https://doi.org/10.1056/nejm198210283071801
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.