Mortality among Diabetic Patients Using Continuous Subcutaneous Insulin-Infusion Pumps
The DOI matches its Crossref record.
Abstract
Because of concern about deaths among diabetic patients using continuous subcutaneous insulin-infusion pumps, we conducted an investigation to determine whether the number of such deaths was excessive. By October 1982 we had identified 35 deaths among the estimated 3500 diabetic patients using pumps in the United States. The observed number of deaths was not greater than the expected number calculated from age-specific death rates for conventionally treated patients with Type I diabetes. The causes of death were not unusual, with two exceptions. One death was associated with malfunction of the device, and the other was attributed to acute bacterial endocarditis that arose from an abscess at the catheter-insertion site. Patients who died had high rates of autonomic neuropathy (66 per cent) and renal disease (39 per cent with serum creatinine levels above 5 mg per deciliter). We conclude that the use of continuous subcutaneous insulin-infusion pumps is not associated with excess mortality. However, certain types of patients may be at greater risk for death, and physicians should take great care in selecting patients for pump therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Management of Hyperglycemic Crises in Patients With Diabetes
Kitabchi, A. E., Umpierrez, G. E., Murphy, M. B., Barrett, E. J., Kreisberg, R. A., Malone, J. I., & Wall, B. M. (2001) · Diabetes Care · doi:10.2337/diacare.24.1.131 · Cited by 710
Unexplained Deaths of Type 1 Diabetic Patients
Tattersall, R. B., & Gill, G. V. (1991) · Diabetic Medicine · doi:10.1111/j.1464-5491.1991.tb01516.x · Cited by 309
Hypoglycemia: causes, neurological manifestations, and outcome.
Malouf, R., & Brust, J. C. M. (1985) · Annals of Neurology · doi:10.1002/ana.410170502 · Cited by 286
Clinical and cost-effectiveness of continuous subcutaneous insulin infusion for diabetes
Colquitt, J., Green, C., Sidhu, M., Hartwell, D., & Waugh, N. (2004) · Health Technology Assessment · doi:10.3310/hta8430 · Cited by 249
Feldt-Rasmussen, B., Mathiesen, E. R., Jensen, T., Lauritzen, T., & Deckert, T. (1991) · Diabetologia · doi:10.1007/bf00418270 · Cited by 222
“Despite an increased risk of ketoacidosis and of hypoglycaemia, the treatment with infusion pumps has been considered safe and not associated with excess mortality in 3500 patients selected for this treatment in the USA in 1982 [34].”
Background
Metadata
- Authors
- Teutsch, S. M., Herman, W. H., Dwyer, D. M., & Lane, J. M.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1984-02-09
- Volume
- 310
- Issue
- 6
- Pages
- 361-368
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2055674251
- Cited by
- 112
- References
- 0
- FWCI
- 12.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mortality among Diabetic Patients Using Continuous Subcutaneous Insulin-Infusion Pumps. https://app.cochat.ai/papers/10.1056/nejm198402093100606
- The paper
- Teutsch, S. M., Herman, W. H., Dwyer, D. M., & Lane, J. M. (1984). Mortality among Diabetic Patients Using Continuous Subcutaneous Insulin-Infusion Pumps. New England Journal of Medicine. https://doi.org/10.1056/nejm198402093100606
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.