The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Rapid Diagnosis of Intravascular Catheter-Associated Infection by Direct Gram Staining of Catheter Segments
Abstract
We conducted a study to determine the usefulness of the Gram stain in the detection of intravascular catheter-associated infection. A total of 330 intravascular catheters were prospectively collected from adults and children suspected of having such an infection. Semiquantitative solid-agar cultures of the distal catheter tip were correlated with blood cultures. Catheter-associated bacteremia occurred in 34 per cent of cases in which catheter tips were colonized (greater than or equal to 15 colonies per agar plate). There were no cases of catheter-associated bacteremia in patients with uncolonized catheters. Immediately after culture, whole catheter segments were stained by the Gram technique. Gram-negative and gram-positive bacteria and yeast were easily identifiable under oil immersion (X 1000), located predominantly on external catheter surfaces. Any catheter with at least one organism per 20 oil-immersion fields was designated as positive by Gram stain, but the majority of the 41 positive catheters had much larger numbers of organisms. The Gram stain of the catheter tip was 100 per cent sensitive and 96.9 per cent specific for the detection of catheter-tip colonization, with positive and negative predictive values of 83.9 and 100 per cent, respectively. We conclude that a Gram stain of the distal catheter tip is a simple, inexpensive, and accurate test for the rapid diagnosis of intravascular catheter-associated infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marrie, T. J., & Costerton, J. W. (1984) · Journal of Clinical Microbiology · doi:10.1128/jcm.19.5.687-693.1984 · Cited by 327
Cited by
Guidelines for the management of intravascular catheter-related infections
Mermel, L. A., Farr, B. M., Sherertz, R. J., Raad, I. I., O'Grady, N., Harris, J. S., & Craven, D. E. (2001) · Clinical Infectious Diseases · doi:10.1086/320001 · Cited by 1,449
Intravascular-catheter-related infections
Raad, I. (1998) · The Lancet · doi:10.1016/s0140-6736(97)10006-x · Cited by 627
O’Grady, N. P., Barie, P. S., Bartlett, J. G., Bleck, T., Carroll, K., Kalil, A. C., Linden, P., Maki, D. G., Nierman, D., Pasculle, W., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318169eda9 · Cited by 600
Raad, I., Costerton, W., Sabharwal, U., Sadlowski, M., Anaissie, E., & Bodey, G. P. (1993) · Journal of Infectious Diseases · doi:10.1093/infdis/168.2.400 · Cited by 553
Guideline for Prevention of Intravascular-Device-Related Infections
Pearson, M. L., & The Hospital Infection Control Practices Advisory Committee (1996) · Infection Control and Hospital Epidemiology · doi:10.2307/30141155 · Cited by 531
Metadata
- Authors
- Cooper, G. L., & Hopkins, C. C.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1985-05-02
- Volume
- 312
- Issue
- 18
- Pages
- 1142-1147
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2614969379
- Cited by
- 185
- References
- 1
- FWCI
- 38.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid Diagnosis of Intravascular Catheter-Associated Infection by Direct Gram Staining of Catheter Segments. https://app.cochat.ai/papers/10.1056/nejm198505023121802
- The paper
- Cooper, G. L., & Hopkins, C. C. (1985). Rapid Diagnosis of Intravascular Catheter-Associated Infection by Direct Gram Staining of Catheter Segments. New England Journal of Medicine. https://doi.org/10.1056/nejm198505023121802
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.