Incidence of Unwarranted Implantation of Permanent Cardiac Pacemakers in a Large Medical Population
The DOI matches its Crossref record.
Abstract
Because of allegations that the implantation of many permanent cardiac pacemakers has been unjustified, we reviewed the indications for all new pacemakers implanted at 30 hospitals in Philadelphia County between January 1 and June 30, 1983, and paid for by Medicare. Complete chart data were evaluated for 382 implants. We determined whether the indications for implantation were appropriate and adequately documented on the basis of standard clinical practice. Implants were classified as possibly indicated primarily because of inadequate diagnostic evaluation (63 percent) or inadequate documentation of an accepted indication (36 percent). Implants were classified as not indicated primarily because a rhythm abnormality was incorrectly identified as a justifiable indication (84 percent). We found that 168 implants (44 percent) were definitely indicated, 137 (36 percent) possibly indicated, and 77 (20 percent) not indicated. Unwarranted implantation was both prevalent (73 percent of hospitals had an incidence of 10 percent or more) and independent of the type of hospital (university teaching, university-affiliated, and community hospitals). The additional tests most often required to clarify the need for a pacemaker in inadequately evaluated cases included electrophysiologic studies (37 percent) and ambulatory monitoring (31 percent). We conclude that in a large medical population in 1983, the indications for a considerable number of permanent pacemakers were inadequate or incompletely documented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Practice Guidelines We Can Trust
Committee on Standards for Developing Trustworthy Clinical Practice Guidelines, Board on Health Care Services, & Institute of Medicine (2011) · National Academies Press eBooks · doi:10.17226/13058 · Cited by 3,081
Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02528-7 · Cited by 1,266
Chassin, M. R. (1998) · JAMA · doi:10.1001/jama.280.11.1000 · Cited by 1,262
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Committee Members, Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., et al. (2002) · Circulation · doi:10.1161/01.cir.0000035996.46455.09 · Cited by 910
Metadata
- Authors
- Greenspan, A. M., Kay, H. R., Berger, B. C., Greenberg, R. M., Greenspon, A. J., & Gaughan, M. J. S.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1988-01-21
- Volume
- 318
- Issue
- 3
- Pages
- 158-163
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2053381688
- Cited by
- 98
- References
- 0
- FWCI
- 9.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Incidence of Unwarranted Implantation of Permanent Cardiac Pacemakers in a Large Medical Population. https://app.cochat.ai/papers/10.1056/nejm198801213180306
- The paper
- Greenspan, A. M., Kay, H. R., Berger, B. C., Greenberg, R. M., Greenspon, A. J., & Gaughan, M. J. S. (1988). Incidence of Unwarranted Implantation of Permanent Cardiac Pacemakers in a Large Medical Population. New England Journal of Medicine. https://doi.org/10.1056/nejm198801213180306
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.