Contrast Material-Induced Renal Failure in Patients with Diabetes Mellitus, Renal Insufficiency, or Both
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
To determine the risk of nephrotoxicity induced by the infusion of radiographic contrast material, we undertook a prospective study of consecutive patients undergoing radiographic procedures with intravascular contrast material. There were three study groups: patients with diabetes mellitus and normal renal function (n = 85), patients with preexisting renal insufficiency (serum creatinine level, greater than or equal to 150 mumol per liter) without diabetes (n = 101), and patients with both diabetes and renal insufficiency (n = 34). The control group consisted of patients undergoing CT scanning or abdominal imaging procedures without the infusion of contrast material who had diabetes mellitus (n = 59), preexisting renal insufficiency (n = 145), or both (n = 64). Clinically important acute renal failure (defined as an increase of greater than 50 percent in the serum creatinine level) attributable to the contrast material did not occur in nondiabetic patients with preexisting renal insufficiency or in diabetics with normal renal function. The incidence of clinically important contrast-induced renal failure among the diabetic patients with preexisting renal insufficiency was 8.8 percent (95 percent confidence interval, 1.9 to 23.7 percent), as compared with 1.6 percent for the controls. The incidence of acute renal insufficiency, more broadly defined as an increase of greater than 25 percent in the serum creatinine level after the infusion of contrast material, was 11.8 percent among all patients with preexisting renal insufficiency. After the exclusion of patients whose acute renal insufficiency could be attributed to other causes, the incidence was 7.0 percent (95 percent confidence interval, 3.2 to 12.8 percent), as compared with 1.5 percent in the control group. The risk of acute renal insufficiency attributable to the contrast material was therefore 5.5 percent, and the relative risk associated with the infusion of contrast material was 4.7. These rates were similar whether the osmolarity of the contrast material was high or low. We conclude that there is little risk of clinically important nephrotoxicity attributable to contrast material for patients with diabetes and normal renal function or for nondiabetic patients with preexisting renal insufficiency. The risk for those with both diabetes and preexisting renal insufficiency is about 9 percent, which is lower than previously reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hospital-acquired renal insufficiency: A prospective study
Hou, S. H., Bushinsky, D. A., Wish, J. B., Cohen, J. J., & Harrington, J. T. (1983) · The American Journal of Medicine · doi:10.1016/0002-9343(83)90618-6 · Cited by 1,238
Coronary Angiography and Acute Renal Failure in Diabetic Azotemic Nephropathy
Weinrauch, L. A., HEALY, R. W., LELAND, O. S., GOLDSTEIN, H. H., KASSISSIEH, S. D., LIBERTINO, J. A., TAKACS, F. J., & D’Elia, J. A. (1977) · Annals of Internal Medicine · doi:10.7326/0003-4819-86-1-56 · Cited by 172
Cited by
De Rosa, S., Samoni, S., Villa, G., & Ronco, C. (2017) · Blood Purification · doi:10.1159/000452650 · Cited by 5,007
Incidence and Prognostic Importance of Acute Renal Failure After Percutaneous Coronary Intervention
Rihal, C. S., Textor, S. C., Grill, D. E., Berger, P. B., Ting, H. H., Best, P. J., Singh, M., Bell, M. R., Barsness, G. W., Mathew, V., et al. (2002) · Circulation · doi:10.1161/01.cir.0000016043.87291.33 · Cited by 1,712
Acute Renal Failure After Coronary Intervention
McCullough, P. A., Wolyn, R., Rocher, L. L., Levin, R. N., & O’Neill, W. W. (1997) · The American Journal of Medicine · doi:10.1016/s0002-9343(97)00150-2 · Cited by 1,671
Prevention of Radiographic-Contrast-Agent–Induced Reductions in Renal Function by Acetylcysteine
Tepel, M., van der Giet, M., Schwarzfeld, C., Laufer, U., Liermann, D., & Zidek, W. (2000) · New England Journal of Medicine · doi:10.1056/nejm200007203430304 · Cited by 1,588
Nephrotoxic Effects in High-Risk Patients Undergoing Angiography
Aspelin, P., Aubry, P., Fransson, S.-G., Strasser, R., Willenbrock, R., & Berg, K. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021833 · Cited by 1,136
Metadata
- Authors
- Parfrey, P. S., Griffiths, S. M., Barrett, B. J., Paul, M. D., Genge, M., Withers, J., Farid, N., & McManamon, P. J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1989-01-19
- Volume
- 320
- Issue
- 3
- Pages
- 143-149
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2316461329
- Cited by
- 1,011
- References
- 2
- FWCI
- 19.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.