Detection of Deep-Vein Thrombosis by Real-Time B-Mode Ultrasonography
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In 220 consecutive outpatients with clinically suspected deep-vein thrombosis of the leg, we compared contrast venography with real-time B-mode ultrasonography, using the single criterion of vein compressibility with the ultrasound transducer probe. The common femoral and popliteal veins were evaluated for full compressibility (no thrombosis) and noncompressibility (thrombosis). Both veins were fully compressible in 142 of the 143 patients with normal venograms (specificity, 99 percent; 95 percent confidence interval, 97 to 100). All 66 patients with proximal-vein thrombosis had noncompressible femoral veins, popliteal veins, or both (sensitivity, 100 percent; 95 percent confidence interval, 95 to 100). For all patients (including 11 with calf-vein thrombi), sensitivity and specificity were 91 (95 percent confidence interval, 82 to 96) and 99 percent, respectively. The sensitivity for isolated calf-vein thrombosis was only 36 percent. The compression ultrasound test was repeated in a subset of 45 consecutive patients by a second examiner, unaware of the results of the first test, whose results agreed in all patients with those of the first examiner (kappa = 1). We conclude that ultrasonography with the single criterion of vein compressibility is a highly accurate, simple, objective, and reproducible noninvasive method for detecting proximal-vein thrombosis in outpatients with clinically suspected deep-venous thrombosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NATURAL HISTORY OF POSTOPERATIVE DEEP-VEIN THROMBOSIS
Kakkar, V. V., Howe, C. T., Flanc, C., & Clarke, M. B. (1969) · The Lancet · doi:10.1016/s0140-6736(69)90002-6 · Cited by 899
Roentgen Diagnosis of Venous Thrombosis in the Leg
Rabinov, K. (1972) · Archives of Surgery · doi:10.1001/archsurg.1972.04180020014004 · Cited by 740
Serial Impedance Plethysmography for Suspected Deep Venous Thrombosis in Outpatients
Huisman, M. V., Böller, H. R., ten Cate, J. W., & Vreeken, J. (1986) · New England Journal of Medicine · doi:10.1056/nejm198603273141305 · Cited by 354
Self-citationQuantification of Agreement in Psychiatric Diagnosis: A New Approach
Spitzer, R. L. (1967) · Archives of General Psychiatry · doi:10.1001/archpsyc.1967.01730250085012 · Cited by 333
Impedance plethysmography using the occlusive cuff technique in the diagnosis of venous thrombosis.
Hull, R., van Aken, W. G., Hirsh, J., Gallus, A. S., Hoicka, G., Turpie, A. G., Walker, I., & Gent, M. (1976) · Circulation · doi:10.1161/01.cir.53.4.696 · Cited by 250
Real-time B-mode venous ultrasound
Sullivan, E. D., Peter, D. J., & Cranley, J. J. (1984) · Journal of Vascular Surgery · doi:10.1067/mva.1984.avs0010465 · Cited by 167
Utility of Impedance Plethysmography in the Diagnosis of Recurrent Deep-Vein Thrombosis
Huisman, M. V., Büller, H. R., & ten Cate, J. W. (1988) · Archives of Internal Medicine · doi:10.1001/archinte.1988.00380030187029 · Cited by 77
Self-citation
Cited by
10-year follow-up of intensive glucose control in type 2 diabetes
Holman, R. R., Paul, S. K., Bethel, M. A., Matthews, D. R., & Neil, H. A. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806470 · Cited by 7,751
“Follow-up. Patients with normal findings at the initial diagnostic workup were scheduled for an end of follow-up visit after 3 months, which consisted of (1) a standardized interview to assess their general health status, chest or leg complaints, and history of hospital admission for any cause; ( 2 ) a physical examin…”
BackgroundLee, A. Y. Y., Levine, M. N., Baker, R. I., Bowden, C., Kakkar, A. K., Prins, M., Rickles, F. R., Julian, J. A., Haley, S., Kovacs, M. J., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa025313 · Cited by 2,534
Wells, P. S., Anderson, D. R., Rodger, M., Stiell, I., Dreyer, J. F., Barnes, D., Forgie, M., Kovacs, G., Ward, J., & Kovacs, M. J. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-2-200107170-00010 · Cited by 1,438
Value of assessment of pretest probability of deep-vein thrombosis in clinical management
Wells, P. S., Anderson, D. R., Bormanis, J., Guy, F., Mitchell, M., Gray, L., Clement, C., Robinson, K. S., & Lewandowski, B. (1997) · The Lancet · doi:10.1016/s0140-6736(97)08140-3 · Cited by 1,229
Levine, M., Gent, M., Hirsh, J., Leclerc, J., Anderson, D., Weitz, J., Ginsberg, J., Turpie, A. G., Demers, C., Kovacs, M., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199603143341101 · Cited by 1,192
Metadata
- Authors
- Lensing, A. W. A., Prandoni, P., Brandjes, D., Huisman, P. M., Vigo, M., Tomasella, G., Krekt, J., ten Cate, J. W., Huisman, M. V., & Büller, H. R.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1989-02-09
- Volume
- 320
- Issue
- 6
- Pages
- 342-345
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2320798046
- Cited by
- 875
- References
- 7
- FWCI
- 48.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.