Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 365

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

A Comparison of Electrophysiologic Testing with Holter Monitoring to Predict Antiarrhythmic-Drug Efficacy for Ventricular Tachyarrhythmias

Open access
Mason, Jay W.·1993·New England Journal of Medicine

Abstract

BACKGROUND: Invasive electrophysiologic study and noninvasive Holter monitoring (in conjunction with exercise testing) have both been used to evaluate the efficacy of antiarrhythmic drugs in patients with sustained ventricular tachycardia and in survivors of cardiac arrest. We directly compared these two approaches to the prediction of drug efficacy. METHODS: A total of 486 patients who had documented ventricular tachyarrhythmias that were inducible during electrophysiologic study and 10 or more premature ventricular complexes per hour during Holter monitoring were randomly assigned to undergo serial testing of antiarrhythmic-drug efficacy by electrophysiologic study or Holter monitoring. The patients received up to six drugs in random order until one was predicted to be effective either in suppressing inducible arrhythmia (in the electrophysiologic-study group) or in suppressing premature ventricular complexes (in the Holter-monitoring group). The patients were then followed for recurrences of arrhythmia or death. RESULTS: In the electrophysiologic-study group, 108 of 242 patients (45 percent) received a prediction of efficacy, as compared with 188 of 244 patients (77 percent) in the Holter-monitoring group (P < 0.001). Over a six-year follow-up period, there were 150 recurrences of arrhythmia and 46 deaths among the 296 patients receiving drugs predicted to be effective. Thirty-four of the deaths were from arrhythmic causes, and eight were from cardiac causes. There was no significant difference between the two study groups in the actuarial probabilities of these events. The risk of a recurrence of arrhythmia was significantly lower in patients who received sotalol than in those who received other antiarrhythmic drugs, and the risk was lower in those who had not previously failed to respond to antiarrhythmic drugs than in those who had. CONCLUSIONS: Although Holter monitoring led to predictions of antiarrhythmic-drug efficacy more often than did electrophysiologic study in patients with sustained ventricular tachyarrhythmias, there was no significant difference in the success of drug therapy as selected by the two methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199308123290701

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 365

Metadata

Authors
Mason, J. W.
Venue
New England Journal of Medicine
Published
1993-08-12
Volume
329
Issue
7
Pages
445-451
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2339648799
Cited by
365
References
16
FWCI
33.30
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison of Electrophysiologic Testing with Holter Monitoring to Predict Antiarrhythmic-Drug Efficacy for Ventricular Tachyarrhythmias. https://app.cochat.ai/papers/10.1056/nejm199308123290701
The paper
Mason, J. W. (1993). A Comparison of Electrophysiologic Testing with Holter Monitoring to Predict Antiarrhythmic-Drug Efficacy for Ventricular Tachyarrhythmias. New England Journal of Medicine. https://doi.org/10.1056/nejm199308123290701

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.