The Urea Reduction Ratio and Serum Albumin Concentration as Predictors of Mortality in Patients Undergoing Hemodialysis
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Among patients with end-stage renal disease who are treated with hemodialysis, solute clearance during dialysis and nutritional adequacy are determinants of mortality. We determined the effects of reductions in blood urea nitrogen concentrations during dialysis and changes in serum albumin concentrations, as an indicator of nutritional status, on mortality in a large group of patients treated with hemodialysis. METHODS: We analyzed retrospectively the demographic characteristics, mortality rate, duration of hemodialysis, serum albumin concentration, and urea reduction ratio (defined as the percent reduction in blood urea nitrogen concentration during a single dialysis treatment) in 13,473 patients treated from October 1, 1990, through March 31, 1991. The risk of death was determined as a function of the urea reduction ratio and serum albumin concentration. RESULTS: As compared with patients with urea reduction ratios of 65 to 69 percent, patients with values below 60 percent had a higher risk of death during follow-up (odds ratio, 1.28 for urea reduction ratios of 55 to 59 percent and 1.39 for ratios below 55 percent). Fifty-five percent of the patients had urea reduction ratios below 60 percent. The duration of dialysis was not predictive of mortality. The serum albumin concentration was a more powerful (21 times greater) predictor of death than the urea reduction ratio, and 60 percent of the patients had serum albumin concentrations predictive of an increased risk of death (values below 4.0 g per deciliter). The odds ratio for death was 1.48 for serum albumin concentrations of 3.5 to 3.9 g per deciliter and 3.13 for concentrations of 3.0 to 3.4 g per deciliter. Diabetic patients had lower serum albumin concentrations and urea reduction ratios than nondiabetic patients. CONCLUSIONS: Low urea reduction ratios during dialysis are associated with increased odds ratios for death. These risks are worsened by inadequate nutrition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1990) · Choice Reviews Online · doi:10.5860/choice.27-3338 · Cited by 35,305
Lowrie, E. G., & Lew, N. L. (1990) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(12)70364-5 · Cited by 1,976
Self-citationA mechanistic analysis of the National Cooperative Dialysis Study (NCDS)
Gotch, F. A., & Sargent, J. A. (1985) · Kidney International · doi:10.1038/ki.1985.160 · Cited by 1,298
Best Subsets Logistic Regression
Hosmer, D. W., Jovanovic, B., & Lemeshow, S. (1989) · Biometrics · doi:10.2307/2531779 · Cited by 1,176
Serum Albumin Level on Admission as a Predictor of Death, Length of Stay, and Readmission
Herrmann, F. R. (1992) · Archives of Internal Medicine · doi:10.1001/archinte.152.1.125 · Cited by 457
Lowrie, E. G., & Lew, N. L. (1992) · PubMed · Cited by 111
Self-citationNutritional Assessment of Intensive-Care Unit Patients
Murray, M. J., Marsh, H. W., Wochos, D. N., Moxness, K. E., Offord, K. P., & Callaway, C. W. (1988) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)65505-0 · Cited by 75
Quantitating Hemodialysis: A Comparison of Three Kinetic Models
Flanigan, M. J., Fangman, J., & LIM, V. S. (1991) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(12)80477-x · Cited by 32
Cited by
Effect of Dialysis Dose and Membrane Flux in Maintenance Hemodialysis
Eknoyan, G., Beck, G. J., Cheung, A. K., Daugirdas, J. T., Greene, T., Kusek, J. W., Allon, M., Bailey, J., Delmez, J. A., Depner, T. A., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa021583 · Cited by 1,882
Inflammation enhances cardiovascular risk and mortality in hemodialysis patients
Zimmermann, J., Herrlinger, S., Pruy, A., Metzger, T., & Wanner, C. (1999) · Kidney International · doi:10.1046/j.1523-1755.1999.00273.x · Cited by 1,531
K/DOQI Clinical Practice Guidelines for Cardiovascular Disease in Dialysis Patients
(2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2005.01.019 · Cited by 1,427
KDOQI Clinical Practice Guideline for Hemodialysis Adequacy: 2015 Update
Daugirdas, J. T., Depner, T. A., Inrig, J., Mehrotra, R., Rocco, M. V., Suri, R. S., Weiner, D. E., Greer, N., Ishani, A., MacDonald, R., et al. (2015) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2015.07.015 · Cited by 1,320
Clinical and echocardiographic disease in patients starting end-stage renal disease therapy
Foley, R. N., Parfrey, P. S., Harnett, J. D., Kent, G. M., Martin, C. J., Murray, D. C., & Barre, P. E. (1995) · Kidney International · doi:10.1038/ki.1995.22 · Cited by 1,299
Metadata
- Authors
- Owen, W. F., Lew, N. L., Liu, Y., Lowrie, E. G., & Lazarus, J. M.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1993-09-30
- Volume
- 329
- Issue
- 14
- Pages
- 1001-1006
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2333333141
- Cited by
- 1,404
- References
- 8
- FWCI
- 42.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.