Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 2,589

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Use of a Monoclonal Antibody Directed against the Platelet Glycoprotein IIb/IIIa Receptor in High-Risk Coronary Angioplasty

Open access
·1994·New England Journal of Medicine

Abstract

BACKGROUND: Platelets are believed to play a part in the ischemic complications of coronary angioplasty, such as abrupt closure of the coronary vessel during or soon after the procedure. Accordingly, we evaluated the effect of a chimeric monoclonal-antibody Fab fragment (c7E3 Fab) directed against the platelet glycoprotein IIb/IIIa receptor, in patients undergoing angioplasty who were at high risk for ischemic complications. This receptor is the final common pathway for platelet aggregation. METHODS: In a prospective, randomized, double-blind trial, 2099 patients treated at 56 centers received a bolus and an infusion of placebo, a bolus of c7E3 Fab and an infusion of placebo, or a bolus and an infusion of c7E3 Fab. They were scheduled to undergo coronary angioplasty or atherectomy in high-risk clinical situations involving severe unstable angina, evolving acute myocardial infarction, or high-risk coronary morphologic characteristics. The primary study end point consisted of any of the following: death, nonfatal myocardial infarction, unplanned surgical revascularization, unplanned repeat percutaneous procedure, unplanned implantation of a coronary stent, or insertion of an intraaortic balloon pump for refractory ischemia. The numbers of end-point events were tabulated for 30 days after randomization. RESULTS: As compared with placebo, the c7E3 Fab bolus and infusion resulted in a 35 percent reduction in the rate of the primary end point (12.8 vs. 8.3 percent, P = 0.008), whereas a 10 percent reduction was observed with the c7E3 Fab bolus alone (12.8 vs. 11.5 percent, P = 0.43). The reduction in the number of events with the c7E3 Fab bolus and infusion was consistent across the end points of unplanned revascularization procedures and nonfatal myocardial infarction. Bleeding episodes and transfusions were more frequent in the group given the c7E3 Fab bolus and infusion than in the other two groups. CONCLUSIONS: Ischemic complications of coronary angioplasty and atherectomy were reduced with a monoclonal antibody directed against the platelet IIb/IIIa glycoprotein receptor, although the risk of bleeding was increased.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199404073301402

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 2,589

Metadata

Venue
New England Journal of Medicine
Published
1994-04-07
Volume
330
Issue
14
Pages
956-961
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W3022148767
Cited by
2,589
References
1
FWCI
120.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of a Monoclonal Antibody Directed against the Platelet Glycoprotein IIb/IIIa Receptor in High-Risk Coronary Angioplasty. https://app.cochat.ai/papers/10.1056/nejm199404073301402
The paper
Use of a Monoclonal Antibody Directed against the Platelet Glycoprotein IIb/IIIa Receptor in High-Risk Coronary Angioplasty. (1994). New England Journal of Medicine. https://doi.org/10.1056/nejm199404073301402

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.