Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 865

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Inhaled Nitric Oxide in Full-Term and Nearly Full-Term Infants with Hypoxic Respiratory Failure

Open access
·1997·New England Journal of Medicine

Abstract

BACKGROUND: Neonates with pulmonary hypertension have been treated with inhaled nitric oxide because of studies suggesting that it is a selective pulmonary vasodilator. We conducted a randomized, multicenter, controlled trial to determine whether inhaled nitric oxide would reduce mortality or the initiation of extracorporeal membrane oxygenation in infants with hypoxic respiratory failure. METHODS: Infants born after a gestation of > or =34 weeks who were 14 days old or less, had no structural heart disease, and required assisted ventilation and whose oxygenation index was 25 or higher on two measurements were eligible for the study. The infants were randomly assigned to receive nitric oxide at a concentration of 20 ppm or 100 percent oxygen (as a control). Infants whose partial pressure of arterial oxygen (PaO2) increased by 20 mm Hg or less after 30 minutes were studied for a response to 80-ppm nitric oxide or control gas. RESULTS: The 121 infants in the control group and the 114 in the nitric oxide group had similar base-line clinical characteristics. Sixty-four percent of the control group and 46 percent of the nitric oxide group died within 120 days or were treated with extracorporeal membrane oxygenation (P=0.006). Seventeen percent of the control group and 14 percent of the nitric oxide group died (P not significant), but significantly fewer in the nitric oxide group received extracorporeal membrane oxygenation (39 percent vs. 54 percent, P=0.014). The nitric oxide group had significantly greater improvement in PaO2 (increase, 58.2+/-85.2 mm Hg, vs. 9.7+/-51.7 mm Hg in the controls; P<0.001) and in the oxygenation index (a decrease of 14.1+/-21.1, vs. an increase of 0.8+/-21.1 in the controls; P<0.001). The study gas was not discontinued in any infant because of toxicity. CONCLUSIONS: Nitric oxide therapy reduced the use of extracorporeal membrane oxygenation, but had no apparent effect on mortality in critically ill infants with hypoxic respiratory failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199702273360901

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 865

Metadata

Venue
New England Journal of Medicine
Published
1997-02-27
Volume
336
Issue
9
Pages
597-604
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2591539149
Cited by
865
References
2
FWCI
62.17
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inhaled Nitric Oxide in Full-Term and Nearly Full-Term Infants with Hypoxic Respiratory Failure. https://app.cochat.ai/papers/10.1056/nejm199702273360901
The paper
Inhaled Nitric Oxide in Full-Term and Nearly Full-Term Infants with Hypoxic Respiratory Failure. (1997). New England Journal of Medicine. https://doi.org/10.1056/nejm199702273360901

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.