The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Prophylactic Use of Implanted Cardiac Defibrillators in Patients at High Risk for Ventricular Arrhythmias after Coronary-Artery Bypass Graft Surgery
Open accessAbstract
BACKGROUND: Patients with coronary heart disease, left ventricular dysfunction, and abnormalities on signal-averaged electrocardiograms have an increased risk sudden death. We evaluated the effect on survival of the prophylactic implantation of cardioverter-defibrillators in such patients at the time of coronary-artery bypass surgery. METHODS: Over the course of five years, 37 clinical centers screened all patients who were scheduled for elective coronary bypass surgery. Patients were eligible for the trial if they were less than 80 years old, had a left ventricular ejection fraction of less than 0.36, and had abnormalities on signal-averaged electrocardiograms. We identified 1422 eligible patients, enrolled 1055, and randomly assigned 900 to therapy with an implantable cardioverter-defibrillator (446 patients) or to the control group (454 patients). The primary end point of the study was overall mortality, and the two groups were compared in an intention-to-treat analysis. RESULTS: The base-line characteristics of the two groups were similar. During an average follow-up of 32+/-16 months, there were 101 deaths in the defibrillator group (71 from cardiac causes) and 95 in the control group (72 from cardiac causes). The hazard ratio for death from any cause was 1.07 (95 percent confidence interval, 0.81 to 1.42; P=0.64). There was no statistically significant interaction between defibrillator therapy and any of 10 preselected base-line covariates. CONCLUSIONS: We found no evidence of improved survival among patients with coronary heart disease, a depressed left ventricular ejection fraction, and an abnormal signal-averaged electrocardiogram in whom a defibrillator was implanted prophylactically at the time of elective coronary bypass surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
The SOLVD Investigators* (1991) · New England Journal of Medicine · doi:10.1056/nejm199108013250501 · Cited by 8,029
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Cohn, J. N., Johnson, G., Ziesche, S., Cobb, F., Francis, G., Tristani, F., Smith, R., Dunkman, W. B., Loeb, H., Wong, M., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199108013250502 · Cited by 2,833
Discrete sequential boundaries for clinical trials
GORDON LAN, K. K., & DEMETS, D. L. (1983) · Biometrika · doi:10.1093/biomet/70.3.659 · Cited by 2,310
Cited by
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.012 · Cited by 2,862
Zipes, D. P., & Wellens, H. J. J. (1998) · Circulation · doi:10.1161/01.cir.98.21.2334 · Cited by 2,744
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Metadata
- Authors
- Bigger, J. T.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1997-11-27
- Volume
- 337
- Issue
- 22
- Pages
- 1569-1575
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2315836251
- Cited by
- 1,020
- References
- 5
- FWCI
- 37.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prophylactic Use of Implanted Cardiac Defibrillators in Patients at High Risk for Ventricular Arrhythmias after Coronary-Artery Bypass Graft Surgery. https://app.cochat.ai/papers/10.1056/nejm199711273372201
- The paper
- Bigger, J. T. (1997). Prophylactic Use of Implanted Cardiac Defibrillators in Patients at High Risk for Ventricular Arrhythmias after Coronary-Artery Bypass Graft Surgery. New England Journal of Medicine. https://doi.org/10.1056/nejm199711273372201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.