Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 575

The DOI matches its Crossref record.

Improvement of Sleep Apnea in Patients with Chronic Renal Failure Who Undergo Nocturnal Hemodialysis

Open access
Hanly, Patrick J., Pierratos, Andreas·2001·New England Journal of Medicine

Abstract

BACKGROUND: Sleep apnea is common in patients with chronic renal failure and is not improved by either conventional hemodialysis or peritoneal dialysis. With nocturnal hemodialysis, patients undergo hemodialysis seven nights per week at home while sleeping. We hypothesized that nocturnal hemodialysis would correct sleep apnea in patients with chronic renal failure because of its greater effectiveness. METHODS: Fourteen patients who were undergoing conventional hemodialysis for four hours on each of three days per week underwent overnight polysomnography. The patients were then switched to nocturnal hemodialysis for eight hours during each of six or seven nights a week. They underwent polysomnography again 6 to 15 months later on one night when they were undergoing nocturnal hemodialysis and on another night when they were not. RESULTS: The mean (+/-SD) serum creatinine concentration was significantly lower during the period when the patients were undergoing nocturnal hemodialysis than during the period when they were undergoing conventional hemodialysis (3.9+/-1.1 vs. 12.8+/-3.2 mg per deciliter [342+/-101 vs. 1131+/-287 micromol per liter], P<0.001). The conversion from conventional hemodialysis to nocturnal hemodialysis was associated with a reduction in the frequency of apnea and hypopnea from 25+/-25 to 8+/-8 episodes per hour of sleep (P=0.03). This reduction occurred predominantly in seven patients with sleep apnea, in whom the frequency of episodes fell from 46+/-19 to 9+/-9 per hour (P= 0.006), accompanied by increases in the minimal oxygen saturation (from 89.2+/-1.8 to 94.1+/-1.6 percent, P=0.005), transcutaneous partial pressure of carbon dioxide (from 38.5+/-4.3 to 48.3+/-4.9 mm Hg, P=0.006), and serum bicarbonate concentration (from 23.2+/-1.8 to 27.8+/-0.8 mmol per liter, P<0.001). During the period when these seven patients were undergoing nocturnal hemodialysis, the apnea-hypopnea index measured on nights when they were not undergoing nocturnal hemodialysis was greater than that on nights when they were undergoing nocturnal hemodialysis, but it still remained lower than it had been during the period when they were undergoing conventional hemodialysis (P=0.05). CONCLUSIONS: Nocturnal hemodialysis corrects sleep apnea associated with chronic renal failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm200101113440204

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 575

Metadata

Authors
Hanly, P. J., & Pierratos, A.
Venue
New England Journal of Medicine
Published
2001-01-11
Volume
344
Issue
2
Pages
102-107
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2106967227
Cited by
575
References
0
FWCI
13.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improvement of Sleep Apnea in Patients with Chronic Renal Failure Who Undergo Nocturnal Hemodialysis. https://app.cochat.ai/papers/10.1056/nejm200101113440204
The paper
Hanly, P. J., & Pierratos, A. (2001). Improvement of Sleep Apnea in Patients with Chronic Renal Failure Who Undergo Nocturnal Hemodialysis. New England Journal of Medicine. https://doi.org/10.1056/nejm200101113440204

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.