Use of Doppler Ultrasonography to Predict the Outcome of Therapy for Renal-Artery Stenosis
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Prospectively identifying patients whose renal function or blood pressure will improve after the correction of renal-artery stenosis has not been possible. We evaluated whether a high level of resistance to flow in the segmental arteries of both kidneys (indicated by resistance-index values of at least 80) can be used prospectively to select appropriate patients for treatment. METHODS: We evaluated 5950 patients with hypertension for renal-artery stenosis using color Doppler ultrasonography, and we measured the resistance index ([1 - end-diastolic velocity divided by maximal systolic velocity] x 100). Among 138 patients who had unilateral or bilateral renal-artery stenosis of more than 50 percent of the luminal diameter and who underwent renal angioplasty or surgery, the procedure was technically successful in 131 (95 percent). Creatinine clearance and 24-hour ambulatory blood pressure were measured before renal-artery stenosis was corrected; 3, 6, and 12 months after the procedure; and yearly thereafter. The mean (+/-SD) duration of follow-up was 32+/-21 months. RESULTS: Among the 35 patients (27 percent) who had resistance-index values of at least 80 before revascularization, the mean arterial pressure did not decrease by 10 mm Hg or more after revascularization in 34 (97 percent). Renal function declined (defined by a decrease in the creatinine clearance; of at least 10 percent) in 28 (80 percent); 16 (46 percent) became dependent on dialysis and 10 (29 percent) died during follow-up. Among the 96 patients (73 percent) with a resistance-index value of less than 80, the mean arterial pressure decreased by at least 10 percent in all but 6 patients (6 percent) after revascularization; renal function worsened in only 3 (3 percent), all of whom became dependent on dialysis; and 3 (3 percent) died (P<0.001 for the comparison with patients with a resistance-index value of at least 80). CONCLUSIONS: A renal resistance-index value of at least 80 reliably identifies patients with renal-artery stenosis in whom angioplasty or surgery will not improve renal function, blood pressure, or kidney survival.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effect of Balloon Angioplasty on Hypertension in Atherosclerotic Renal-Artery Stenosis
van Jaarsveld, B. C., Krijnen, P., Pieterman, H., Derkx, F. H. M., Deinum, J., Postma, C. T., Dees, A., Woittiez, A. J. J., Bartelink, A. K. M., Man in `t Veld, A. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200004063421403 · Cited by 897
Ramsay, L. E., & WALLER, P. C. (1990) · BMJ · doi:10.1136/bmj.300.6724.569 · Cited by 238
Renal Revascularization to Preserve and Restore Renal Function
Libertino, J. A., Bosco, P. J., Ying, C. Y., Breslin, D. J., Woods, B. O., Tsapatsaris, N. P., & Swinton, N. W. (1992) · The Journal of Urology · doi:10.1016/s0022-5347(17)37603-6 · Cited by 94
Circulating levels of angiotensin I measured by radioimmunoassay in hypertensive subjects.
Workman, R. J., Sussman, C., Burkitt, D. W., & Liddle, G. W. (1979) · PubMed · Cited by 52
Keller, F. (1987) · Nephrology Dialysis Transplantation · doi:10.1093/oxfordjournals.ndt.a091583 · Cited by 39
Renal Parenchymal Involvement in Essential Hypertension
Schwartz, G. L., & Strong, C. G. (1987) · Medical Clinics of North America · doi:10.1016/s0025-7125(16)30812-4 · Cited by 38
Tullis, M. J., Zierler, R. E., Caps, M. T., Bergelin, R. O., Cantwell-Gab, K., & Strandness, D. E. (1998) · Annals of Vascular Surgery · doi:10.1007/s100169900127 · Cited by 31
Cited by
Hirsch, A. T., Haskal, Z. J., Hertzer, N. R., Bakal, C. W., Creager, M. A., Halperin, J. L., Hiratzka, L. F., Murphy, W. R. C., Olin, J. W., Puschett, J. B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.174526 · Cited by 3,708
on behalf of The Japanese Society of Hypertension Committee for Guidelines for the Management of Hypertension, Ogihara, T., Kikuchi, K., Matsuoka, H., Fujita, T., Higaki, J., Horiuchi, M., Imai, Y., Imaizumi, T., Ito, S., et al. (2014) · Hypertension Research · doi:10.1038/hr.2014.68 · Cited by 1,385
Hirsch, A. T., Haskal, Z. J., Hertzer, N. R., Bakal, C. W., Creager, M. A., Halperin, J. L., Hiratzka, L. F., Murphy, W. R. C., Olin, J. W., Puschett, J. B., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.009 · Cited by 1,021
Slovut, D. P., & Olin, J. W. (2004) · New England Journal of Medicine · doi:10.1056/nejmra032393 · Cited by 744
Slovut, D. P., & Olin, J. W. (2005) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-005-0017-z · Cited by 591
Metadata
- Authors
- Radermacher, J., Chavan, A., Bleck, J., Vitzthum, A., Stoess, B., Gebel, M. J., Galanski, M., Koch, K. M., & Haller, H.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2001-02-08
- Volume
- 344
- Issue
- 6
- Pages
- 410-417
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2312236630
- Cited by
- 780
- References
- 7
- FWCI
- 33.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.