The DOI matches its Crossref record.
A Synthetic Pentasaccharide for the Prevention of Deep-Vein Thrombosis after Total Hip Replacement
Open accessAbstract
BACKGROUND: Venous thromboembolism is a frequent complication of total hip replacement. The pentasaccharide Org31540/SR90107A, a highly selective, indirect inhibitor of activated factor X, is the first of a new class of synthetic antithrombotic agents. To determine the optimal dose for phase 3 studies, we conducted a dose-ranging study in which Org31540/SR90107A was compared with a low-molecular-weight heparin, enoxaparin, in patients undergoing total hip replacement. METHODS: In a double-blind study, patients were randomly assigned to postoperative administration of one of five daily doses of Org31540/SR90107A, given once daily, or to 30 mg of enoxaparin, given every 12 hours. Treatment was continued for 10 days or until bilateral venography was performed after a minimum of 5 days. RESULTS: Of 933 patients treated, 593 were eligible for the efficacy analysis. With Org31540/SR90107A a dose effect was observed (P=0.002), with rates of venous thromboembolism of 11.8 percent, 6.7 percent, 1.7 percent, 4.4 percent, and 0 percent for the groups assigned to 0.75 mg, 1.5 mg, 3.0 mg, 6.0 mg, and 8.0 mg of the drug, respectively, as compared with a rate of 9.4 percent in the enoxaparin group. The reduction in the risk of venous thromboembolism was 82 percent for the 3.0-mg Org31540/SR90107A group (P=0.01) and 29 percent for the 1.5-mg group (P=0.51). Enrollment in the 6.0-mg and 8.0-mg Org31540/SR90107A groups was discontinued because of bleeding complications. Major bleeding occurred 3.5 percent less frequently in the 0.75-mg group (P=0.01) and 3.0 percent less frequently in the 1.5-mg group (P=0.05) than in the enoxaparin group (in which the rate was similar to that in the 3.0-mg group). CONCLUSIONS: A synthetic pentasaccharide, Org31540/SR90107A, has the potential to improve significantly the risk-benefit ratio for the prevention of venous thromboembolism, as compared with low-molecular-weight heparin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reilly, P. A., Lehr, T., Haertter, S., Connolly, S. J., Yusuf, S., Eikelboom, J. W., Ezekowitz, M. D., Nehmiz, G., Wang, S., & Wallentin, L. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.07.104 · Cited by 834
Eriksson, B. I., Bauer, K. A., Lassen, M. R., & Turpie, A. G. G. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011100 · Cited by 631
Self-citationModel-Based Drug Development: A Rational Approach to Efficiently Accelerate Drug Development
Milligan, P. A., Brown, M. J., Marchant, B., Martin, S. W., van der Graaf, P. H., Benson, N., Nucci, G., Nichols, D. J., Boyd, R. A., Mandema, J. W., et al. (2013) · Clinical Pharmacology & Therapeutics · doi:10.1038/clpt.2013.54 · Cited by 238
Methodological issues in trials assessing primary prophylaxis of venous thrombo-embolism
Thabut, G., Estellat, C., Boutron, I., Samama, C. M., & Ravaud, P. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi587 · Cited by 11
Metadata
- Authors
- Turpie, A. G. G., Gallus, A. S., & Hoek, J. A.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2001-03
- Volume
- 344
- Issue
- 9
- Pages
- 619-625
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2321004276
- Cited by
- 380
- References
- 0
- FWCI
- 33.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Synthetic Pentasaccharide for the Prevention of Deep-Vein Thrombosis after Total Hip Replacement. https://app.cochat.ai/papers/10.1056/nejm200103013440901
- The paper
- Turpie, A. G. G., Gallus, A. S., & Hoek, J. A. (2001). A Synthetic Pentasaccharide for the Prevention of Deep-Vein Thrombosis after Total Hip Replacement. New England Journal of Medicine. https://doi.org/10.1056/nejm200103013440901
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.