The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
High-Frequency Oscillatory Ventilation versus Conventional Mechanical Ventilation for Very-Low-Birth-Weight Infants
Open accessAbstract
BACKGROUND: The efficacy and safety of early high-frequency oscillatory ventilation as compared with conventional synchronized intermittent mandatory ventilation for the treatment of infants with very low birth weight have not been established. METHODS: We conducted a randomized, multicenter clinical trial to determine whether infants treated with early high-frequency oscillatory ventilation were more likely than infants treated with synchronized intermittent mandatory ventilation to be alive without requiring supplemental oxygen at 36 weeks of postmenstrual age. Eligible infants weighed 601 to 1200 g at birth, were less than four hours of age, had received one dose of surfactant, and required ventilation with a mean airway pressure of at least 6 cm of water and a fraction of inspired oxygen of at least 0.25. Infants were stratified according to birth weight and exposure to prenatal corticosteroids and then randomly assigned to high-frequency oscillatory ventilation or synchronized intermittent mandatory ventilation. Ventilation was managed according to protocols designed to optimize lung inflation and blood gas values. RESULTS: Five hundred infants were enrolled in the study. Infants randomly assigned to high-frequency oscillatory ventilation were successfully extubated earlier than infants assigned to synchronized intermittent mandatory ventilation (P<0.001). Of infants assigned to high-frequency oscillatory ventilation, 56 percent were alive without a need for supplemental oxygen at 36 weeks of postmenstrual age, as compared with 47 percent of those receiving synchronized intermittent mandatory ventilation (P=0.046). There was no difference between the groups in the risk of intracranial hemorrhage, cystic periventricular leukomalacia, or other complications. CONCLUSIONS: There was a small but significant benefit of high-frequency oscillatory ventilation in terms of the pulmonary outcome for very-low-birth-weight infants without an increase in the occurrence of other complications of premature birth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Papile, L.-A., Burstein, J., Burstein, R., & Koffler, H. (1978) · The Journal of Pediatrics · doi:10.1016/s0022-3476(78)80282-0 · Cited by 6,430
Changing trends in the epidemiology and pathogenesis of neonatal chronic lung disease
Rojas, M. A., Gonzalez, A., Bancalari, E., Claure, N., Poole, C., & Silva-Neto, G. (1995) · The Journal of Pediatrics · doi:10.1016/s0022-3476(95)70362-4 · Cited by 474
Low‐dose indomethacin and prevention of intraventricular hemorrhage: A multicenter randomized trial
Ment, L. R., Ehrenkranz, R. A., Duncan, C. C., Scott, D. T., Taylor, K. J. W., Katz, K. H., Schneider, K. C., Makuch, R. W., Oh, W., Vohr, B., et al. (1994) · Pediatrics · doi:10.1542/peds.93.4.543 · Cited by 385
Stevenson, D. K., Wright, L. L., Lemons, J. A., Oh, W., Korones, S. B., Papile, L.-A., Bauer, C. R., Stoll, B. J., Tyson, J. E., Shankaran, S., et al. (1998) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(98)70037-7 · Cited by 294
Bilateral Cystic Periventricular Leukomalacia in the Premature Infant: Associated Risk Factors
Perlman, J. M., Risser, R., & Broyles, R. S. (1996) · Pediatrics · doi:10.1542/peds.97.6.822 · Cited by 272
YODER, B. A., SILER-KHODR, T., WINTER, V. T., & COALSON, J. J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.5.9912145 · Cited by 194
Froese, A. B., McCulloch, P. R., Sugiura, M., et al. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.3.569 · Cited by 194
Moriette, G., Paris-Llado, J., Walti, H., Escande, B., Magny, J.-F., Cambonie, G., Thiriez, G., Cantagrel, S., Lacaze-Masmonteil, T., Storme, L., et al. (2001) · Pediatrics · doi:10.1542/peds.107.2.363 · Cited by 177
Synnes, A. R., Chien, L.-Y., Peliowski, A., Baboolal, R., & Lee, S. K. (2001) · The Journal of Pediatrics · doi:10.1067/mpd.2001.111822 · Cited by 160
Cited by
Kinsella, J. P., Greenough, A., & Abman, S. H. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68615-7 · Cited by 454
Diagnostic markers of infection in neonates
Ng, P. C. (2004) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/adc.2002.023838 · Cited by 298
Synchronized mechanical ventilation for respiratory support in newborn infants
Greenough, A., Rossor, T. E., Sundaresan, A., Murthy, V., & Milner, A. D. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000456.pub5 · Cited by 255
Metadata
- Authors
- Courtney, S. E., Durand, D. J., Asselin, J. M., Hudak, M. L., Aschner, J. L., & Shoemaker, C. T.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2002-08-29
- Volume
- 347
- Issue
- 9
- Pages
- 643-652
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2014967817
- Cited by
- 418
- References
- 18
- FWCI
- 23.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Frequency Oscillatory Ventilation versus Conventional Mechanical Ventilation for Very-Low-Birth-Weight Infants. https://app.cochat.ai/papers/10.1056/nejmoa012750
- The paper
- Courtney, S. E., Durand, D. J., Asselin, J. M., Hudak, M. L., Aschner, J. L., & Shoemaker, C. T. (2002). High-Frequency Oscillatory Ventilation versus Conventional Mechanical Ventilation for Very-Low-Birth-Weight Infants. New England Journal of Medicine. https://doi.org/10.1056/nejmoa012750
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.