Balloon Angioplasty versus Implantation of Nitinol Stents in the Superficial Femoral Artery

Open access
Schillinger, Martin, Sabeti, Schila, Loewe, Christian, Dick, Petra, Amighi, Jasmin, Mlekusch, Wolfgang, Schlager, Oliver, Cejna, Manfred, Lammer, Johannes, Minar, Erich·2006·New England Journal of Medicine

Abstract

BACKGROUND: Because stent implantation for disease of the superficial femoral artery has been associated with high rates of late clinical failure, percutaneous transluminal angioplasty is preferred for endovascular treatment, and stenting is recommended only in the event of suboptimal technical results. We evaluated whether primary implantation of a self-expanding nitinol (nickel-titanium) stent yielded anatomical and clinical benefits superior to those afforded by percutaneous transluminal angioplasty with optional secondary stenting. METHODS: We randomly assigned 104 patients who had severe claudication or chronic limb ischemia due to stenosis or occlusion of the superficial femoral artery to undergo primary stent implantation (51 patients) or angioplasty (53 patients). Restenosis and clinical outcomes were assessed at 6 and 12 months. RESULTS: The mean (+/-SD) length of the treated segment was 132+/-71 mm in the stent group and 127+/-55 mm in the angioplasty group. Secondary stenting was performed in 17 of 53 patients (32 percent) in the angioplasty group, in most cases because of a suboptimal result after angioplasty. At 6 months, the rate of restenosis on angiography was 24 percent in the stent group and 43 percent in the angioplasty group (P=0.05); at 12 months the rates on duplex ultrasonography were 37 percent and 63 percent, respectively (P=0.01). Patients in the stent group were able to walk significantly farther on a treadmill at 6 and 12 months than those in the angioplasty group. CONCLUSIONS: In the intermediate term, treatment of superficial-femoral-artery disease by primary implantation of a self-expanding nitinol stent yielded results that were superior to those with the currently recommended approach of balloon angioplasty with optional secondary stenting. (ClinicalTrials.gov number, NCT00281060.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa051303

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,157

Metadata

Authors
Schillinger, M., Sabeti, S., Loewe, C., Dick, P., Amighi, J., Mlekusch, W., Schlager, O., Cejna, M., Lammer, J., & Minar, E.
Venue
New England Journal of Medicine
Published
2006-05-04
Volume
354
Issue
18
Pages
1879-1888
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2569906950
Cited by
1,157
References
0
FWCI
62.65
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Balloon Angioplasty versus Implantation of Nitinol Stents in the Superficial Femoral Artery. https://app.cochat.ai/papers/10.1056/nejmoa051303
The paper
Schillinger, M., Sabeti, S., Loewe, C., Dick, P., Amighi, J., Mlekusch, W., Schlager, O., Cejna, M., Lammer, J., & Minar, E. (2006). Balloon Angioplasty versus Implantation of Nitinol Stents in the Superficial Femoral Artery. New England Journal of Medicine. https://doi.org/10.1056/nejmoa051303

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.