Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 704

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

A Pooled Analysis of Data Comparing Sirolimus-Eluting Stents with Bare-Metal Stents

Open access
Spaulding, Christian, Daemen, Joost, Boersma, Eric, Cutlip, Donald E., Serruys, Patrick W.·2007·New England Journal of Medicine

Abstract

BACKGROUND: Although randomized studies have shown a beneficial effect of drug-eluting stents in reducing the risk of repeated revascularization, these trials were underpowered to compare rates of death and myocardial infarction. The long-term safety of drug-eluting stents has been questioned recently. METHODS: We performed a pooled analysis of 1748 patients in four randomized trials evaluating the safety of sirolimus-eluting stents as compared with bare-metal stents. Patient-level data were obtained and analyzed by independent statisticians at two academic institutions. The primary safety end point was survival at 4 years. We tested for heterogeneities in treatment effect in patient subgroups. RESULTS: The survival rate at 4 years was 93.3% in the sirolimus-stent group, as compared with 94.6% in the bare-metal-stent group (hazard ratio for death, 1.24; 95% confidence interval [CI], 0.84 to 1.83; P=0.28). In the 428 patients with diabetes, a significant difference in the survival rate was observed in favor of the bare-metal-stent group over the sirolimus-stent group (95.6% vs. 87.8%; hazard ratio for death in the sirolimus-stent group, 2.9; 95% CI, 1.38 to 6.10; P=0.008). The lower survival rate among patients with diabetes who were treated with sirolimus-eluting stents was due to increased numbers of deaths from both cardiovascular and noncardiovascular causes. No difference in survival rate was detected among the patients without diabetes. Rates of myocardial infarction and stent thrombosis were similar in the two groups. CONCLUSIONS: In a pooled analysis of data from four trials comparing sirolimus-eluting stents and bare-metal stents, no significant differences were found between the two treatments in rates of death, myocardial infarction, or stent thrombosis. (ClinicalTrials.gov numbers, NCT00233805 [ClinicalTrials.gov] , NCT00381420 [ClinicalTrials.gov] , NCT00232765 [ClinicalTrials.gov] , and NCT00235144 [ClinicalTrials.gov].)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa066633

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 704

Metadata

Authors
Spaulding, C., Daemen, J., Boersma, E., Cutlip, D. E., & Serruys, P. W.
Venue
New England Journal of Medicine
Published
2007-03-08
Volume
356
Issue
10
Pages
989-997
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2092998815
Cited by
704
References
20
FWCI
127.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Pooled Analysis of Data Comparing Sirolimus-Eluting Stents with Bare-Metal Stents. https://app.cochat.ai/papers/10.1056/nejmoa066633
The paper
Spaulding, C., Daemen, J., Boersma, E., Cutlip, D. E., & Serruys, P. W. (2007). A Pooled Analysis of Data Comparing Sirolimus-Eluting Stents with Bare-Metal Stents. New England Journal of Medicine. https://doi.org/10.1056/nejmoa066633

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.