The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
High-Flow Nasal Cannulae in Very Preterm Infants after Extubation
Open accessAbstract
BACKGROUND: The use of high-flow nasal cannulae is an increasingly popular alternative to nasal continuous positive airway pressure (CPAP) for noninvasive respiratory support of very preterm infants (gestational age, <32 weeks) after extubation. However, data on the efficacy or safety of such cannulae in this population are lacking. METHODS: In this multicenter, randomized, noninferiority trial, we assigned 303 very preterm infants to receive treatment with either high-flow nasal cannulae (5 to 6 liters per minute) or nasal CPAP (7 cm of water) after extubation. The primary outcome was treatment failure within 7 days. Noninferiority was determined by calculating the absolute difference in the risk of the primary outcome; the margin of noninferiority was 20 percentage points. Infants in whom treatment with high-flow nasal cannulae failed could be treated with nasal CPAP; infants in whom nasal CPAP failed were reintubated. RESULTS: The use of high-flow nasal cannulae was noninferior to the use of nasal CPAP, with treatment failure occurring in 52 of 152 infants (34.2%) in the nasal-cannulae group and in 39 of 151 infants (25.8%) in the CPAP group (risk difference, 8.4 percentage points; 95% confidence interval, -1.9 to 18.7). Almost half the infants in whom treatment with high-flow nasal cannulae failed were successfully treated with CPAP without reintubation. The incidence of nasal trauma was significantly lower in the nasal-cannulae group than in the CPAP group (P=0.01), but there were no significant differences in rates of serious adverse events or other complications. CONCLUSIONS: Although the result for the primary outcome was close to the margin of noninferiority, the efficacy of high-flow nasal cannulae was similar to that of CPAP as respiratory support for very preterm infants after extubation. (Funded by the National Health and Medical Research Council; Australian New Zealand Clinical Trials Network number, ACTRN12610000166077.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piaggio, G., Elbourne, D. R., Pocock, S. J., Evans, S. J. W., Altman, D. G., & CONSORT Group, F. T. (2012) · JAMA · doi:10.1001/jama.2012.87802 · Cited by 2,428
Births: preliminary data for 2012.
Hamilton, B. E., Martin, J. A., & Ventura, S. J. (2013) · PubMed · Cited by 1,509
Reporting of Noninferiority and Equivalence Randomized Trials: An Extension of the CONSORT Statement
Piaggio, G., Elbourne, D. R., Altman, D. G., Pocock, S. J., Evans, S. J. W., & CONSORT Group, F. T. (2006) · JAMA · doi:10.1001/jama.295.10.1152 · Cited by 1,153
High flow nasal cannula for respiratory support in preterm infants
Wilkinson, D., Andersen, C., O'Donnell, C. P., De Paoli, A. G., & Manley, B. J. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006405.pub3 · Cited by 368
Self-citationNeonatal non‐invasive respiratory support: Physiological implications
Shaffer, T. H., Alapati, D., Greenspan, J. S., & Wolfson, M. R. (2012) · Pediatric Pulmonology · doi:10.1002/ppul.22610 · Cited by 40
Cited by
Hernández, G., Vaquero, C., González, P., Subira, C., Frutos-Vivar, F., Rialp, G., Laborda, C., Colinas, L., Cuena, R., & Fernández, R. (2016) · JAMA · doi:10.1001/jama.2016.2711 · Cited by 551
Maggiore, S. M., Idone, F. A., Vaschetto, R., Festa, R., Cataldo, A., Antonicelli, F., Montini, L., De Gaetano, A., Navalesi, P., & Antonelli, M. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201402-0364oc · Cited by 546
Stéphan, F., Barrucand, B., Petit, P., Rézaiguia-Delclaux, S., Médard, A., Delannoy, B., Cosserant, B., Flicoteaux, G., Imbert, A., Pilorge, C., et al. (2015) · JAMA · doi:10.1001/jama.2015.5213 · Cited by 535
A Randomized Trial of High-Flow Oxygen Therapy in Infants with Bronchiolitis
Franklin, D., Babl, F. E., Schlapbach, L. J., Oakley, E., Craig, S., Neutze, J., Furyk, J., Fraser, J. F., Jones, M., Whitty, J. A., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1714855 · Cited by 442
High flow nasal cannula for respiratory support in preterm infants
Wilkinson, D., Andersen, C., O'Donnell, C. P., De Paoli, A. G., & Manley, B. J. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006405.pub3 · Cited by 368
Self-citation
Metadata
- Authors
- Manley, B. J., Owen, L. S., Doyle, L. W., Andersen, C. C., Cartwright, D. W., Pritchard, M. A., Donath, S. M., & Davis, P. G.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2013-10-10
- Volume
- 369
- Issue
- 15
- Pages
- 1425-1433
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2129212558
- Cited by
- 345
- References
- 5
- FWCI
- 28.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.