Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 504

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Oxygen Saturation and Outcomes in Preterm Infants

Open access
The BOOST II United Kingdom, Australia, and New Zealand Collaborative Groups·2013·New England Journal of Medicine

Abstract

BACKGROUND: The clinically appropriate range for oxygen saturation in preterm infants is unknown. Previous studies have shown that infants had reduced rates of retinopathy of prematurity when lower targets of oxygen saturation were used. METHODS: In three international randomized, controlled trials, we evaluated the effects of targeting an oxygen saturation of 85 to 89%, as compared with a range of 91 to 95%, on disability-free survival at 2 years in infants born before 28 weeks' gestation. Halfway through the trials, the oximeter-calibration algorithm was revised. Recruitment was stopped early when an interim analysis showed an increased rate of death at 36 weeks in the group with a lower oxygen saturation. We analyzed pooled data from patients and now report hospital-discharge outcomes. RESULTS: A total of 2448 infants were recruited. Among the 1187 infants whose treatment used the revised oximeter-calibration algorithm, the rate of death was significantly higher in the lower-target group than in the higher-target group (23.1% vs. 15.9%; relative risk in the lower-target group, 1.45; 95% confidence interval [CI], 1.15 to 1.84; P=0.002). There was heterogeneity for mortality between the original algorithm and the revised algorithm (P=0.006) but not for other outcomes. In all 2448 infants, those in the lower-target group for oxygen saturation had a reduced rate of retinopathy of prematurity (10.6% vs. 13.5%; relative risk, 0.79; 95% CI, 0.63 to 1.00; P=0.045) and an increased rate of necrotizing enterocolitis (10.4% vs. 8.0%; relative risk, 1.31; 95% CI, 1.02 to 1.68; P=0.04). There were no significant between-group differences in rates of other outcomes or adverse events. CONCLUSIONS: Targeting an oxygen saturation below 90% with the use of current oximeters in extremely preterm infants was associated with an increased risk of death. (Funded by the Australian National Health and Medical Research Council and others; BOOST II Current Controlled Trials number, ISRCTN00842661, and Australian New Zealand Clinical Trials Registry numbers, ACTRN12605000055606 and ACTRN12605000253606.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1302298

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 504

Metadata

Authors
The BOOST II United Kingdom, A.
Venue
New England Journal of Medicine
Published
2013-05-30
Volume
368
Issue
22
Pages
2094-2104
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W208036677
Cited by
504
References
13
FWCI
46.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oxygen Saturation and Outcomes in Preterm Infants. https://app.cochat.ai/papers/10.1056/nejmoa1302298
The paper
The BOOST II United Kingdom, A. (2013). Oxygen Saturation and Outcomes in Preterm Infants. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1302298

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.