The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Ultrasonography versus Computed Tomography for Suspected Nephrolithiasis
Open accessAbstract
BACKGROUND: There is a lack of consensus about whether the initial imaging method for patients with suspected nephrolithiasis should be computed tomography (CT) or ultrasonography. METHODS: In this multicenter, pragmatic, comparative effectiveness trial, we randomly assigned patients 18 to 76 years of age who presented to the emergency department with suspected nephrolithiasis to undergo initial diagnostic ultrasonography performed by an emergency physician (point-of-care ultrasonography), ultrasonography performed by a radiologist (radiology ultrasonography), or abdominal CT. Subsequent management, including additional imaging, was at the discretion of the physician. We compared the three groups with respect to the 30-day incidence of high-risk diagnoses with complications that could be related to missed or delayed diagnosis and the 6-month cumulative radiation exposure. Secondary outcomes were serious adverse events, related serious adverse events (deemed attributable to study participation), pain (assessed on an 11-point visual-analogue scale, with higher scores indicating more severe pain), return emergency department visits, hospitalizations, and diagnostic accuracy. RESULTS: A total of 2759 patients underwent randomization: 908 to point-of-care ultrasonography, 893 to radiology ultrasonography, and 958 to CT. The incidence of high-risk diagnoses with complications in the first 30 days was low (0.4%) and did not vary according to imaging method. The mean 6-month cumulative radiation exposure was significantly lower in the ultrasonography groups than in the CT group (P<0.001). Serious adverse events occurred in 12.4% of the patients assigned to point-of-care ultrasonography, 10.8% of those assigned to radiology ultrasonography, and 11.2% of those assigned to CT (P=0.50). Related adverse events were infrequent (incidence, 0.4%) and similar across groups. By 7 days, the average pain score was 2.0 in each group (P=0.84). Return emergency department visits, hospitalizations, and diagnostic accuracy did not differ significantly among the groups. CONCLUSIONS: Initial ultrasonography was associated with lower cumulative radiation exposure than initial CT, without significant differences in high-risk diagnoses with complications, serious adverse events, pain scores, return emergency department visits, or hospitalizations. (Funded by the Agency for Healthcare Research and Quality.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735
Health Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
Mathews, J. D., Forsythe, A. V., Brady, Z., Butler, M. W., Goergen, S. K., Byrnes, G. B., Giles, G. G., Wallace, A. B., Anderson, P. R., Guiver, T. A., et al. (2013) · BMJ · doi:10.1136/bmj.f2360 · Cited by 2,029
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Preston, D. L., Ron, E., Tokuoka, S., Funamoto, S., Nishi, N., Soda, M., Mabuchi, K., & Kodama, K. (2007) · Radiation Research · doi:10.1667/rr0763.1 · Cited by 1,753
UROLOGIC DISEASES IN AMERICA PROJECT: UROLITHIASIS
PEARLE, M. S., CALHOUN, E. A., CURHAN, G. C., & the UROLOGIC DISEASES OF AMERICA PROJECT (2005) · Journal of Urology · doi:10.1097/01.ju.0000152082.14384.d7 · Cited by 941
Smith-Bindman, R., Miglioretti, D. L., Johnson, E., Lee, C., Feigelson, H. S., Flynn, M., Greenlee, R. T., Kruger, R. L., Hornbrook, M. C., Roblin, D., et al. (2012) · JAMA · doi:10.1001/jama.2012.5960 · Cited by 898
Self-citationConverting Dose-Length Product to Effective Dose at CT
Huda, W., Ogden, K. M., & Khorasani, M. R. (2008) · Radiology · doi:10.1148/radiol.2483071964 · Cited by 513
Incidental findings in imaging diagnostic tests: a systematic review
Lumbreras, B., Donat, L., & Hernández-Aguado, I. (2010) · The British Journal of Radiology · doi:10.1259/bjr/98067945 · Cited by 370
Fwu, C.-W., Eggers, P. W., Kimmel, P. L., Kusek, J. W., & Kirkali, Z. (2013) · Kidney International · doi:10.1038/ki.2012.419 · Cited by 221
Westphalen, A. C., Hsia, R. Y., Maselli, J. H., Wang, R., & Gonzales, R. (2011) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2011.01103.x · Cited by 175
Self-citationWorster, A., Preyra, I., Weaver, B., & Haines, T. (2002) · Annals of Emergency Medicine · doi:10.1067/mem.2002.126170 · Cited by 173
Cited by
Ultrasound Guidelines: Emergency, Point-of-Care and Clinical Ultrasound Guidelines in Medicine
(2017) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2016.08.457 · Cited by 646
Determining the true burden of kidney stone disease
Thongprayoon, C., Krambeck, A. E., & Rule, A. D. (2020) · Nature Reviews Nephrology · doi:10.1038/s41581-020-0320-7 · Cited by 409
An overview of kidney stone imaging techniques
Brisbane, W., Bailey, M. R., & Sorensen, M. D. (2016) · Nature Reviews Urology · doi:10.1038/nrurol.2016.154 · Cited by 391
Wang, R. C., Rodriguez, R. M., Moghadassi, M., Noble, V., Bailitz, J., Mallin, M., Corbo, J., Kang, T. L., Chu, P., Shiboski, S., et al. (2016) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2015.08.019 · Cited by 68
Self-citation
Metadata
- Authors
- Smith-Bindman, R., Aubin, C., Bailitz, J., Bengiamin, R. N., Camargo, C. A., Corbo, J., Dean, A. J., Goldstein, R. B., Griffey, R. T., Jay, G. D., Kang, T. L., Kriesel, D. R., Ma, O. J., Mallin, M., Manson, W., Melnikow, J., Miglioretti, D. L., Miller, S. K., Mills, L. D., Miner, J. R., Moghadassi, M., Noble, V. E., Press, G. M., Stoller, M. L., Valencia, V. E., Wang, J., Wang, R. C., & Cummings, S. R.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2014-09-18
- Volume
- 371
- Issue
- 12
- Pages
- 1100-1110
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2143939700
- Cited by
- 653
- References
- 11
- FWCI
- 51.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.