Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 722

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Remote Ischemic Preconditioning and Outcomes of Cardiac Surgery

Open access
Hausenloy, Derek J., Candilio, Luciano, Evans, Richard, Ariti, Cono, Jenkins, David P., Kolvekar, Shyam, Knight, Rosemary, Kunst, Gudrun, Laing, Christopher, Nicholas, Jennifer, Pepper, John, Robertson, Steven, Xenou, Maria, Clayton, Tim, Yellon, Derek M.·2015·New England Journal of Medicine

Abstract

BACKGROUND: Whether remote ischemic preconditioning (transient ischemia and reperfusion of the arm) can improve clinical outcomes in patients undergoing coronary-artery bypass graft (CABG) surgery is not known. We investigated this question in a randomized trial. METHODS: We conducted a multicenter, sham-controlled trial involving adults at increased surgical risk who were undergoing on-pump CABG (with or without valve surgery) with blood cardioplegia. After anesthesia induction and before surgical incision, patients were randomly assigned to remote ischemic preconditioning (four 5-minute inflations and deflations of a standard blood-pressure cuff on the upper arm) or sham conditioning (control group). Anesthetic management and perioperative care were not standardized. The combined primary end point was death from cardiovascular causes, nonfatal myocardial infarction, coronary revascularization, or stroke, assessed 12 months after randomization. RESULTS: We enrolled a total of 1612 patients (811 in the control group and 801 in the ischemic-preconditioning group) at 30 cardiac surgery centers in the United Kingdom. There was no significant difference in the cumulative incidence of the primary end point at 12 months between the patients in the remote ischemic preconditioning group and those in the control group (212 patients [26.5%] and 225 patients [27.7%], respectively; hazard ratio with ischemic preconditioning, 0.95; 95% confidence interval, 0.79 to 1.15; P=0.58). Furthermore, there were no significant between-group differences in either adverse events or the secondary end points of perioperative myocardial injury (assessed on the basis of the area under the curve for the high-sensitivity assay of serum troponin T at 72 hours), inotrope score (calculated from the maximum dose of the individual inotropic agents administered in the first 3 days after surgery), acute kidney injury, duration of stay in the intensive care unit and hospital, distance on the 6-minute walk test, and quality of life. CONCLUSIONS: Remote ischemic preconditioning did not improve clinical outcomes in patients undergoing elective on-pump CABG with or without valve surgery. (Funded by the Efficacy and Mechanism Evaluation Program [a Medical Research Council and National Institute of Health Research partnership] and the British Heart Foundation; ERICCA ClinicalTrials.gov number, NCT01247545.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1413534

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 722

Metadata

Authors
Hausenloy, D. J., Candilio, L., Evans, R., Ariti, C., Jenkins, D. P., Kolvekar, S., Knight, R., Kunst, G., Laing, C., Nicholas, J., Pepper, J., Robertson, S., Xenou, M., Clayton, T., & Yellon, D. M.
Venue
New England Journal of Medicine
Published
2015-10-08
Volume
373
Issue
15
Pages
1408-1417
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2325867355
Cited by
722
References
18
FWCI
76.86
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Remote Ischemic Preconditioning and Outcomes of Cardiac Surgery. https://app.cochat.ai/papers/10.1056/nejmoa1413534
The paper
Hausenloy, D. J., Candilio, L., Evans, R., Ariti, C., Jenkins, D. P., Kolvekar, S., Knight, R., Kunst, G., Laing, C., Nicholas, J., Pepper, J., Robertson, S., Xenou, M., Clayton, T., & Yellon, D. M. (2015). Remote Ischemic Preconditioning and Outcomes of Cardiac Surgery. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1413534

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.