Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 223

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Nasal High-Flow Therapy for Primary Respiratory Support in Preterm Infants

Open access
Roberts, Calum T., Owen, Louise S., Manley, Brett J., Frøisland, Dag H., Donath, Susan M., Dalziel, Kim M., Pritchard, Margo A., Cartwright, David W., Collins, Clare L., Malhotra, Atul, Davis, Peter G.·2016·New England Journal of Medicine

Abstract

BACKGROUND: Treatment with nasal high-flow therapy has efficacy similar to that of nasal continuous positive airway pressure (CPAP) when used as postextubation support in neonates. The efficacy of high-flow therapy as the primary means of respiratory support for preterm infants with respiratory distress has not been proved. METHODS: In this international, multicenter, randomized, noninferiority trial, we assigned 564 preterm infants (gestational age, ≥28 weeks 0 days) with early respiratory distress who had not received surfactant replacement to treatment with either nasal high-flow therapy or nasal CPAP. The primary outcome was treatment failure within 72 hours after randomization. Noninferiority was determined by calculating the absolute difference in the risk of the primary outcome; the chosen margin of noninferiority was 10 percentage points. Infants in whom high-flow therapy failed could receive rescue CPAP; infants in whom CPAP failed were intubated and mechanically ventilated. RESULTS: Trial recruitment stopped early at the recommendation of the independent data and safety monitoring committee because of a significant difference in the primary outcome between treatment groups. Treatment failure occurred in 71 of 278 infants (25.5%) in the high-flow group and in 38 of 286 infants (13.3%) in the CPAP group (risk difference, 12.3 percentage points; 95% confidence interval [CI], 5.8 to 18.7; P<0.001). The rate of intubation within 72 hours did not differ significantly between the high-flow and CPAP groups (15.5% and 11.5%, respectively; risk difference, 3.9 percentage points; 95% CI, -1.7 to 9.6; P=0.17), nor did the rate of adverse events. CONCLUSIONS: When used as primary support for preterm infants with respiratory distress, high-flow therapy resulted in a significantly higher rate of treatment failure than did CPAP. (Funded by the National Health and Medical Research Council and others; Australian New Zealand Clinical Trials Registry number, ACTRN12613000303741 .).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1603694

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 223

Metadata

Authors
Roberts, C. T., Owen, L. S., Manley, B. J., Frøisland, D. H., Donath, S. M., Dalziel, K. M., Pritchard, M. A., Cartwright, D. W., Collins, C. L., Malhotra, A., & Davis, P. G.
Venue
New England Journal of Medicine
Published
2016-09-22
Volume
375
Issue
12
Pages
1142-1151
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2466586463
Cited by
223
References
1
FWCI
22.51
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nasal High-Flow Therapy for Primary Respiratory Support in Preterm Infants. https://app.cochat.ai/papers/10.1056/nejmoa1603694
The paper
Roberts, C. T., Owen, L. S., Manley, B. J., Frøisland, D. H., Donath, S. M., Dalziel, K. M., Pritchard, M. A., Cartwright, D. W., Collins, C. L., Malhotra, A., & Davis, P. G. (2016). Nasal High-Flow Therapy for Primary Respiratory Support in Preterm Infants. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1603694

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.