CoChat

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Self-Contained Neuromusculoskeletal Arm Prostheses

Open access
Ortiz-Catalan, Max, Mastinu, Enzo, Sassu, Paolo, Aszmann, Oskar, Brånemark, Rickard · 2020 · New England Journal of Medicine

Abstract

We report the use of a bone-anchored, self-contained robotic arm with both sensory and motor components over 3 to 7 years in four patients after transhumeral amputation. The implant allowed for bidirectional communication between a prosthetic hand and electrodes implanted in the nerves and muscles of the upper arm and was anchored to the humerus through osseointegration, the process in which bone cells attach to an artificial surface without formation of fibrous tissue. Use of the device did not require formal training and depended on the intuitive intent of the user to activate movement and sensory feedback from the prosthesis. Daily use resulted in increasing sensory acuity and effectiveness in work and other activities of daily life. (Funded by the Promobilia Foundation and others.).

Overview

Integrity signals

Registry

Crossref · 10.1056/nejmoa1917537

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 20 references

Cited by

See all 256

Metadata

Authors
Ortiz-Catalan, M., Mastinu, E., Sassu, P., Aszmann, O., & Brånemark, R.
Affiliations
Sahlgrenska University Hospital (SE)
Venue
New England Journal of Medicine
Published
2020-04-30
Volume
382
Issue
18
Pages
1732-1738
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W3019274887
Cited by
256
References
20
Citations by year
2026: 45 · 2025: 31 · 2024: 34 · 2023: 35 · 2022: 48 · 2021: 49 · 2020: 14
FWCI
16.79
Type
journal article
Language
en
Open access
Locations
  • New England Journal of Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Chalmers Research (Chalmers University of Technology) (submittedVersion)
  • CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
  • Zenodo (CERN European Organization for Nuclear Research) (cc-by)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
transhumeral amputation, osseointegration, bone-anchored prosthesis, neuromuscular control, sensory feedback, myoelectric control, upper limb prosthesis, activities of daily living
MeSH terms
Adult, Amputation, Surgical, Amputation, Traumatic, Artificial Limbs, Humans, Humerus, Male, Middle Aged, Prosthesis Design, Robotics, Osseointegration, Implantable Neurostimulators

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-Contained Neuromusculoskeletal Arm Prostheses. https://app.cochat.ai/papers/10.1056/nejmoa1917537
The paper
Ortiz-Catalan, M., Mastinu, E., Sassu, P., Aszmann, O., & Brånemark, R. (2020). Self-Contained Neuromusculoskeletal Arm Prostheses. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1917537

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.