The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Defibrillation Strategies for Refractory Ventricular Fibrillation
Open accessAbstract
BACKGROUND: Despite advances in defibrillation technology, shock-refractory ventricular fibrillation remains common during out-of-hospital cardiac arrest. Double sequential external defibrillation (DSED; rapid sequential shocks from two defibrillators) and vector-change (VC) defibrillation (switching defibrillation pads to an anterior-posterior position) have been proposed as defibrillation strategies to improve outcomes in patients with refractory ventricular fibrillation. METHODS: We conducted a cluster-randomized trial with crossover among six Canadian paramedic services to evaluate DSED and VC defibrillation as compared with standard defibrillation in adult patients with refractory ventricular fibrillation during out-of-hospital cardiac arrest. Patients were treated with one of these three techniques according to the strategy that was randomly assigned to the paramedic service. The primary outcome was survival to hospital discharge. Secondary outcomes included termination of ventricular fibrillation, return of spontaneous circulation, and a good neurologic outcome, defined as a modified Rankin scale score of 2 or lower (indicating no symptoms to slight disability) at hospital discharge. RESULTS: A total of 405 patients were enrolled before the data and safety monitoring board stopped the trial because of the coronavirus disease 2019 pandemic. A total of 136 patients (33.6%) were assigned to receive standard defibrillation, 144 (35.6%) to receive VC defibrillation, and 125 (30.9%) to receive DSED. Survival to hospital discharge was more common in the DSED group than in the standard group (30.4% vs. 13.3%; relative risk, 2.21; 95% confidence interval [CI], 1.33 to 3.67) and more common in the VC group than in the standard group (21.7% vs. 13.3%; relative risk, 1.71; 95% CI, 1.01 to 2.88). DSED but not VC defibrillation was associated with a higher percentage of patients having a good neurologic outcome than standard defibrillation (relative risk, 2.21 [95% CI, 1.26 to 3.88] and 1.48 [95% CI, 0.81 to 2.71], respectively). CONCLUSIONS: Among patients with refractory ventricular fibrillation, survival to hospital discharge occurred more frequently among those who received DSED or VC defibrillation than among those who received standard defibrillation. (Funded by the Heart and Stroke Foundation of Canada; DOSE VF ClinicalTrials.gov number, NCT04080986.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and analysis of group-randomized trials: a review of recent methodological developments
Murray, D. M., Varnell, S. P., & Blitstein, J. L. (2004) · American Journal of Public Health · doi:10.2105/ajph.94.3.423 · Cited by 677
Cited by
Cascella, M., Montomoli, J., Bellini, V., & Bignami, E. (2023) · Journal of Medical Systems · doi:10.1007/s10916-023-01925-4 · Cited by 1,120
Marijon, E., Narayanan, K., Smith, K., Barra, S., Basso, C., Blom, M. T., Crotti, L., D'Avila, A., Deo, R., Dumas, F., et al. (2023) · The Lancet · doi:10.1016/s0140-6736(23)00875-9 · Cited by 313
Metadata
- Authors
- Cheskes, S., Verbeek, P. R., Drennan, I. R., McLeod, S. L., Turner, L., Pinto, R., Feldman, M., Davis, M., Vaillancourt, C., Morrison, L. J., Dorian, P., & Scales, D. C.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2022-11-24
- Volume
- 387
- Issue
- 21
- Pages
- 1947-1956
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W4308290955
- Cited by
- 233
- References
- 1
- FWCI
- 47.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.