Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 376

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Transcatheter Valve Replacement in Severe Tricuspid Regurgitation

Hahn, Rebecca T., Makkar, Raj, Thourani, Vinod H., Makar, Moody, Sharma, Rahul P., Haeffele, Christiane, Davidson, Charles J., Narang, Akhil, O’Neill, Brian, Lee, James, Yadav, Pradeep, Zahr, Firas, Chadderdon, Scott, Eleid, Mackram, Pislaru, Sorin, Smith, Robert, Szerlip, Molly, Whisenant, Brian, Sekaran, Nishant K., Garcia, Santiago, Stewart-Dehner, Terri, Thiele, Holger, Kipperman, Robert, Koulogiannis, Konstantinos, Lim, D. Scott, Fowler, Dale, Kapadia, Samir, Harb, Serge C., Grayburn, Paul A., Sannino, Anna, Mack, Michael J., Leon, Martin B., Lurz, Philipp, Kodali, Susheel K.·2025·New England Journal of Medicine

Abstract

BACKGROUND: Severe tricuspid regurgitation is associated with disabling symptoms and an increased risk of death. Data regarding outcomes after percutaneous transcatheter tricuspid-valve replacement are needed. METHODS: In this international, multicenter trial, we randomly assigned 400 patients with severe symptomatic tricuspid regurgitation in a 2:1 ratio to undergo either transcatheter tricuspid-valve replacement and medical therapy (valve-replacement group) or medical therapy alone (control group). The hierarchical composite primary outcome was death from any cause, implantation of a right ventricular assist device or heart transplantation, postindex tricuspid-valve intervention, hospitalization for heart failure, an improvement of at least 10 points in the score on the Kansas City Cardiomyopathy Questionnaire overall summary (KCCQ-OS), an improvement of at least one New York Heart Association (NYHA) functional class, and an improvement of at least 30 m on the 6-minute walk distance. A win ratio was calculated for the primary outcome by comparing all possible patient pairs, starting with the first event in the hierarchy. RESULTS: A total of 267 patients were assigned to the valve-replacement group and 133 to the control group. At 1 year, the win ratio favoring valve replacement was 2.02 (95% confidence interval [CI], 1.56 to 2.62; P<0.001). In comparisons of patient pairs, those in the valve-replacement group had more wins than the control group with respect to death from any cause (14.8% vs. 12.5%), postindex tricuspid-valve intervention (3.2% vs. 0.6%), and improvement in the KCCQ-OS score (23.1% vs. 6.0%), NYHA class (10.2% vs. 0.8%), and 6-minute walk distance (1.1% vs. 0.9%). The valve-replacement group had fewer wins than the control group with respect to the annualized rate of hospitalization for heart failure (9.7% vs. 10.0%). Severe bleeding occurred in 15.4% of the valve-replacement group and in 5.3% of the control group (P = 0.003); new permanent pacemakers were implanted in 17.4% and 2.3%, respectively (P<0.001). CONCLUSIONS: For patients with severe tricuspid regurgitation, transcatheter tricuspid-valve replacement was superior to medical therapy alone for the primary composite outcome, driven primarily by improvements in symptoms and quality of life. (Funded by Edwards Lifesciences; TRISCEND II ClinicalTrials.gov number, NCT04482062.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa2401918

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 376

Metadata

Authors
Hahn, R. T., Makkar, R., Thourani, V. H., Makar, M., Sharma, R. P., Haeffele, C., Davidson, C. J., Narang, A., O’Neill, B., Lee, J., Yadav, P., Zahr, F., Chadderdon, S., Eleid, M., Pislaru, S., Smith, R., Szerlip, M., Whisenant, B., Sekaran, N. K., Garcia, S., Stewart-Dehner, T., Thiele, H., Kipperman, R., Koulogiannis, K., Lim, D. S., Fowler, D., Kapadia, S., Harb, S. C., Grayburn, P. A., Sannino, A., Mack, M. J., Leon, M. B., Lurz, P., & Kodali, S. K.
Venue
New England Journal of Medicine
Published
2025-01-09
Volume
392
Issue
2
Pages
115-126
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W4403886925
Cited by
376
References
4
FWCI
101.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcatheter Valve Replacement in Severe Tricuspid Regurgitation. https://app.cochat.ai/papers/10.1056/nejmoa2401918
The paper
Hahn, R. T., Makkar, R., Thourani, V. H., Makar, M., Sharma, R. P., Haeffele, C., Davidson, C. J., Narang, A., O’Neill, B., Lee, J., Yadav, P., Zahr, F., Chadderdon, S., Eleid, M., Pislaru, S., Smith, R., Szerlip, M., Whisenant, B., Sekaran, N. K., . . . Kodali, S. K. (2025). Transcatheter Valve Replacement in Severe Tricuspid Regurgitation. New England Journal of Medicine. https://doi.org/10.1056/nejmoa2401918

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.