Phenomenological Model for Magnetorheological Dampers
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Semiactive control devices have received significant attention in recent years because they offer the adaptability of active control devices without requiring the associated large power sources. Magnetorheological (MR) dampers are semiactive control devices that use MR fluids to produce controllable dampers. They potentially offer highly reliable operation and can be viewed as fail-safe in that they become passive dampers should the control hardware malfunction. To develop control algorithms that take full advantage of the unique features of the MR damper, models must be developed that can adequately characterize the damper's intrinsic nonlinear behavior. Following a review of several idealized mechanical models for controllable fluid dampers, a new model is proposed that can effectively portray the behavior of a typical MR damper. Comparison with experimental results for a prototype damper indicates that the model is accurate over a wide range of operating conditions and is adequate for control design and analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Method for Random Vibration of Hysteretic Systems
Wen, Y.-K. (1976) · Journal of the Engineering Mechanics Division · doi:10.1061/jmcea3.0002106 · Cited by 2,668
Induced Fibration of Suspensions
Winslow, W. M. (1949) · Journal of Applied Physics · doi:10.1063/1.1698285 · Cited by 1,235
Rabinow, J. (1948) · Transactions of the American Institute of Electrical Engineers · doi:10.1109/t-aiee.1948.5059821 · Cited by 633
Active Structural Control: Theory and Practice
Soong, T. T., & Spencer, B. F. (1992) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1992)118:6(1282 · Cited by 574
Self-citationCOMMERCIAL MAGNETO-RHEOLOGICAL FLUID DEVICES
Carlson, J. D., Catanzarite, D. M., & Clair, K. A. S. (1996) · International Journal of Modern Physics B · doi:10.1142/s0217979296001306 · Cited by 546
Self-citationElastic And Inelastic Stress Analysis
Shames, I. H. (1997) · CRC Press eBooks · doi:10.1201/b16599 · Cited by 416
Dynamic mechanical studies of electrorheological materials: Moderate frequencies
Gamota, D. R., & Filisko, F. E. (1991) · Journal of Rheology · doi:10.1122/1.550221 · Cited by 323
Seismic response controlled structure with Active Variable Stiffness system
Kobori, T., Takahashi, M., Nasu, T., Niwa, N., & Ogasawara, K. (1993) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290221102 · Cited by 311
Seismic Response Reduction Using Magnetorheological Dampers
Dyke, S. J., Spencer, B. F., Sain, M. K., & Carlson, J. D. (1996) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)58562-6 · Cited by 207
Self-citationElectrorheological Dampers, Part I: Analysis and Design
Gavin, H. P., Hanson, R. D., & Filisko, F. E. (1996) · Journal of Applied Mechanics · doi:10.1115/1.2823348 · Cited by 207
Electrorheological Dampers, Part II: Testing and Modeling
Gavin, H. P., Hanson, R. D., & Filisko, F. E. (1996) · Journal of Applied Mechanics · doi:10.1115/1.2823349 · Cited by 150
A growing attraction to magnetic fluids
Weiss, K. D., & Carlson, J. D. (1994) · Machine design · Cited by 148
Self-citationModeling the oscillatory dynamic behaviour of electrorheological materials in shear
Ehrgott, R., & Masri, S. F. (1992) · Smart Materials and Structures · doi:10.1088/0964-1726/1/4/002 · Cited by 125
Analysis and Design of ER Damper for Seismic Protection of Structures
Makris, N., Burton, S., Hill, D. A., & Jordan, M. (1996) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1996)122:10(1003 · Cited by 112
Closed loop structural control using electrorheological dampers
McClamroch, N. H., & Gavin, H. P. (2005) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.1995.532717 · Cited by 96
7. An Overview of Active Structural Control under Seismic Loads
Soong, T. T., Masri, S. F., & Housner, G. W. (1991) · Earthquake Spectra · doi:10.1193/1.1585638 · Cited by 71
Actively regulated friction slip braces
Akbay, Z., & Aktan, H. (1991) · University of Toronto Press eBooks · doi:10.3138/9781487583217-047 · Cited by 28
Electrorheological fluid damper for seismic protection of structures
Makris, N., Hill, D. A., Burton, S., & Jordan, M. (1995) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.208256 · Cited by 27
Development of adjustable hydraulic damper for seismic response control of large structures
Mizumo, T., Hirai, J., Kobori, T., Matsunaga, Y., & Niwa, N. (1992) · American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP · Cited by 24
A New Semi-Active Control Device for Seismic Response Reduction
Dyke, S. J., Spencer, B. F., Sain, M. K., & Carlson, J. D. (1996) · Engineering Mechanics · Cited by 12
Self-citation
Cited by
Supplemental energy dissipation: state-of-the-art and state-of-the-practice
Soong, T. T., & Spencer, B. F. (2002) · Engineering Structures · doi:10.1016/s0141-0296(01)00092-x · Cited by 1,220
Self-citationRecent advances in nonlinear passive vibration isolators
Ibrahim, R. A. (2008) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2008.01.014 · Cited by 1,181
The Hysteresis Bouc-Wen Model, a Survey
Ismail, M., Ikhouane, F., & Rodellar, J. (2009) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-009-9031-8 · Cited by 740
Semi-active control systems for seismic protection of structures: a state-of-the-art review
Symans, M. D., & Constantinou, M. C. (1999) · Engineering Structures · doi:10.1016/s0141-0296(97)00225-3 · Cited by 706
Semiactive Control Strategies for MR Dampers: Comparative Study
Jansen, L. M., & Dyke, S. J. (2000) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(2000)126:8(795 · Cited by 614
Self-citation
Metadata
- Authors
- Spencer, B. F., Dyke, S. J., Sain, M. K., & Carlson, J. D.
- Venue
- Journal of Engineering Mechanics
- Published
- 1997-03
- Volume
- 123
- Issue
- 3
- Pages
- 230-238
- ISSN
- 0733-9399 (ISSN-L)
- 1943-7889
- DOI
- 10.1061/(asce)0733-9399(1997)123:3(230
- OpenAlex
- W2071223490
- Cited by
- 2,055
- References
- 20
- FWCI
- 76.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.