New Acoustic Meter for Measuring 3D Laboratory Flows
The DOI matches its Crossref record.
Abstract
A small, robust, and relatively inexpensive current meter was developed to measure uniform and oscillatory water flows in both open‐weather and enclosed‐physical‐model facilities. The 10‐MHz acoustic‐doppler volocimeter (ADV) measures three‐dimensional current velocity over the speed range of 0 to 2.5 m/s at a sampling rate of up to 25 Hz. Measurements are made in a small sampling volume located 5 cm from a slim transmit‐receive assembly. Comparison tests of the ADV in several engineering model facilities together with other velocity‐measurement instruments and in a precision tow‐channel facility were highly successful. The ADV is rugged and portable, and it can remain installed in facilities for extended periods without recalibration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Spatially Averaged Open-Channel Flow over Rough Bed
Nikora, V., Goring, D., McEwan, I., & Griffiths, G. (2001) · Journal of Hydraulic Engineering · doi:10.1061/(asce)0733-9429(2001)127:2(123 · Cited by 498
Flow Velocity Measurements in Vegetated Channels
Carollo, F. G., Ferro, V., & Termini, D. (2002) · Journal of Hydraulic Engineering · doi:10.1061/(asce)0733-9429(2002)128:7(664 · Cited by 246
ADV Measurements of Turbulence: Can We Improve Their Interpretation?
Nikora, V. I., & Goring, D. G. (1998) · Journal of Hydraulic Engineering · doi:10.1061/(asce)0733-9429(1998)124:6(630 · Cited by 238
Turbulence Measurements with Acoustic Doppler Velocimeters
García, C. M., Cantero, M. I., Niño, Y., & García, M. H. (2005) · Journal of Hydraulic Engineering · doi:10.1061/(asce)0733-9429(2005)131:12(1062 · Cited by 216
“Acoustic Doppler velocimeters are capable of reporting accurate mean values of water velocity in three directions Kraus et al. 1994; Lohrmann et al. 1994; Anderson and Lohrmann 1995; Lane et al. 1998; Voulgaris and Trowbridge 1998; Lopez and Garcia 2001 , even in low flow velocities Lohrmann et al. 1994 . However, the…”
BackgroundDoron, P., Bertuccioli, L., Katz, J., & Osborn, T. R. (2001) · Journal of Physical Oceanography · doi:10.1175/1520-0485(2001)031<2108:tcadei>2.0.co;2 · Cited by 194
“The Doppler shift of acoustic signal reflection is also employed in the Acoustic Doppler Velocimeter (ADV) for point measurements of 3D velocity components (Kraus et al. 1994; George 1996; Voulgaris and Trowbridge 1998).”
MethodQuiroz‐Arita, C., Blaylock, M. L., Gharagozloo, P. E., Bark, D., Prasad Dasi, L., & Bradley, T. H. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27268 · Cited by 11
Metadata
- Authors
- Kraus, N. C., Lohrmann, A., & Cabrera, R.
- Venue
- Journal of Hydraulic Engineering
- Published
- 1994-03
- Volume
- 120
- Issue
- 3
- Pages
- 406-412
- ISSN
- 0733-9429 (ISSN-L)
- 1943-7900
- DOI
- 10.1061/(asce)0733-9429(1994)120:3(406
- OpenAlex
- W2042284886
- Cited by
- 198
- References
- 0
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.