The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Seismic Design of Viscoelastic Dampers for Structural Applications
Abstract
Some practical issues associated with the application of viscoelastic (VE) dampers to building structures for seismic performance enhancement are studied in this paper. A sequential procedure is developed for optimally placing VE dampers to structures, based on the concept of degree of controllability. This optimal placement procedure is then experimentally verified using a five‐story steel model structure. Economical use of the VE dampers is made possible by adding them to the optimal locations found by this procedure, as is clearly demonstrated by the numerical examples and experimental results presented in the paper. A design procedure is also presented by which damper dimensions, number, and locations needed to achieve desired level of additional damping can be determined in accordance with the structural parameters and structural‐response reduction requirement. Design of VE dampers for a 24‐story steel frame is presented as an example, showing the complete design procedure for applying VE dampers to realistic structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seismic response of steel frame structures with added viscoelastic dampers
Zhang, R., Soong, T. T., & Mahmoodi, P. (1989) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290180307 · Cited by 124
Self-citationAn experimental study on seismic behaviour of viscoelastically damped structures
Lin, R. C., Liang, Z., Soong, T. T., Zhang, R. H., & Mahmoodi, P. (1991) · Engineering Structures · doi:10.1016/0141-0296(91)90011-z · Cited by 55
Self-citation
Cited by
Seismic control of single‐degree‐of‐freedom structure using tuned viscous mass damper
Ikago, K., Saito, K., & Inoue, N. (2012) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.1138 · Cited by 782
Design strategies of viscous dampers for seismic protection of building structures: A review
De Domenico, D., Ricciardi, G., & Takewaki, I. (2019) · Soil Dynamics and Earthquake Engineering · doi:10.1016/j.soildyn.2018.12.024 · Cited by 347
Optimal placement of dampers for passive response control
Singh, M. P., & Moreschi, L. M. (2002) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.132 · Cited by 291
Structural Control: Past, Present, and Future
(1997) · doi:10.1061/(asce)0733-9399(1997)123:9(897
Metadata
- Authors
- Zhang, R., & Soong, T. T.
- Venue
- Journal of Structural Engineering
- Published
- 1992-05
- Volume
- 118
- Issue
- 5
- Pages
- 1375-1392
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(1992)118:5(1375
- OpenAlex
- W2090201665
- Cited by
- 429
- References
- 2
- FWCI
- 18.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Seismic Design of Viscoelastic Dampers for Structural Applications. https://app.cochat.ai/papers/10.1061/(asce)0733-9445(1992)118:5(1375
- The paper
- Zhang, R., & Soong, T. T. (1992). Seismic Design of Viscoelastic Dampers for Structural Applications. Journal of Structural Engineering. https://doi.org/10.1061/(asce)0733-9445(1992)118%3A5(1375
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.