This paper presents an experimental and analytical study on the behavior of short, concrete-filled steel tube columns concentrically loaded in compression to failure. Fourteen specimens were tested to investigate the effect of the steel tube shape and wall thickness on the ultimate strength of the composite column. Confinement of the concrete core provided by the tube shape was also addressed. Depth-to-tube wall thickness ratios between 17 <D/t< 50, and the length-to-tube depth ratios of 4 <L/D< 5 were investigated. Ultimate strength results were compared to current specifications governing the design of concrete-filled steel tube columns. Nonlinear finite-element models were developed and verified using experimental results. The analytical models were further used to investigate the adequacy of design specifications. Experimental results suggest that circular tubes offer substantial post-yield strength and stiffness, not available in most square or rectangular cross sections. Also observed by these results was that current design specifications were adequate to predict the yield load under most conditions for a variety of structural shapes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Building Code Requirements for Reinforced Concrete
ACI Committee (1962) · ACI Journal Proceedings · doi:10.14359/7919 · Cited by 610
Strength of Steel-Encased Concrete Beam Columns
Furlong, R. W. (1967) · Journal of the Structural Division · doi:10.1061/jsdeag.0001761 · Cited by 310
Strength of Concrete Filled Steel Tubular Columns
Knowles, R. B., & Park, R. (1969) · Journal of the Structural Division · doi:10.1061/jsdeag.0002425 · Cited by 273
Structural Behavior of Concrete Filled Steel Tubes
Gardner, N. J., & Jacobson, E. R. (1967) · ACI Journal Proceedings · doi:10.14359/7575 · Cited by 194
Experimental Studies on Concrete-Filled Steel Tubular Stub Columns under Concentric Loading
Tomii, M., Yoshimura, K., & Morishita, Y. (1977) · Cited by 142
Design of Steel-Encased Concrete Beam-Columns
Furlong, R. W. (1968) · Journal of the Structural Division · doi:10.1061/jsdeag.0001854 · Cited by 74
Cited by
Developments and advanced applications of concrete-filled steel tubular (CFST) structures: Members
Han, L.-H., Li, W., & Bjorhovde, R. (2014) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2014.04.016 · Cited by 1,830
Performance of concrete-filled thin-walled steel tubes under pure torsion
Han, L.-H., Yao, G.-H., & Tao, Z. (2007) · Thin-Walled Structures · doi:10.1016/j.tws.2007.01.008 · Cited by 1,389
Finite element modelling of concrete-filled steel stub columns under axial compression
Tao, Z., Wang, Z.-B., & Yu, Q. (2013) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2013.07.001 · Cited by 1,297
Nonlinear Analysis of Axially Loaded Concrete-Filled Tube Columns with Confinement Effect
Hu, H.-T., Huang, C.-S., Wu, M.-H., & Wu, Y.-M. (2003) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2003)129:10(1322 · Cited by 626
Han, L.-H., Yao, G.-H., & Zhao, X.-L. (2005) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2005.01.004 · Cited by 616
Metadata
- Authors
- Schneider, S. P.
- Venue
- Journal of Structural Engineering
- Published
- 1998-10
- Volume
- 124
- Issue
- 10
- Pages
- 1125-1138
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(1998)124:10(1125
- OpenAlex
- W1992565913
- Cited by
- 816
- References
- 6
- FWCI
- 20.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Axially Loaded Concrete-Filled Steel Tubes. https://app.cochat.ai/papers/10.1061/(asce)0733-9445(1998)124:10(1125
- The paper
- Schneider, S. P. (1998). Axially Loaded Concrete-Filled Steel Tubes. Journal of Structural Engineering. https://doi.org/10.1061/(asce)0733-9445(1998)124%3A10(1125